Normative electromyography data and influencing factors in intraoperative neuromonitoring using adhesive skin electrodes during thyroid surgery
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- GLAND SURGERY13(3) · pp.351 · 2024
- 피인용
- Web of Science 2Scopus 6
- FWCI (Scopus)
- 1.61
- JCR IF
- JCR 2023 1.5
- ISSN
- 2227-684X
저자
- 신성찬제1저자Pusan Natl Univ, Coll Med, Dept Otorhinolaryngol Head & Neck Surg, 179 Gudeok Ro, Busan 49241, South Korea
- 천용일Pusan Natl Univ, Coll Med, Dept Otorhinolaryngol Head & Neck Surg, 179 Gudeok Ro, Busan 49241, South Korea
- 이민형Pusan Natl Univ, Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Yangsan, Gyeongsangnam D, South Korea
- 성의숙Pusan Natl Univ, Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Yangsan, Gyeongsangnam D, South Korea
- 이진춘Pusan Natl Univ, Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Yangsan, Gyeongsangnam D, South Korea
- 김미진Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Internal Med, Div Endocrinol & Metab,Coll Med, Busan, South Korea
- 김보현Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Internal Med, Div Endocrinol & Metab,Coll Med, Busan, South Korea
- 이병주교신저자Pusan Natl Univ, Coll Med, Dept Otorhinolaryngol Head & Neck Surg, 179 Gudeok Ro, Busan 49241, South Korea
초록
Background: Skin electrodes have been reported to be a useful alternative recording method for intraoperative neuromonitoring (IONM) and show typical electromyography (EMG) waveforms while overcoming the shortcomings of the EMG endotracheal tube. However, the skin electrodes showed relatively lower evoked amplitudes than other recording methods. In this study, we analyzed normative EMG data using skin electrodes and factors that affect the evoked amplitude of thyroid IONM.Methods: In total, 167 patients [242 nerves at risk (NAR)] who underwent thyroidectomy under IONM with adhesive skin electrodes were analyzed. A pair of skin electrodes was attached to the lateral border of the lamina of the thyroid cartilage. Evoked EMG data, including mean amplitude and latency, obtained after stimulation of the recurrent laryngeal nerve (RLN) and vagus nerve (VN), were collected and analyzed.Results: The mean amplitudes of RLN and VN recorded via skin electrodes were 255.48 +/- 96.53 and 236.15 +/- 69.72 mu V, respectively. The mean latency of the right and left RLN was 3.22 +/- 0.03 and 3.49 +/- 0.08 mS, respectively. The mean latency of the right and left VN was 5.37 +/- 0.80 and 7.57 +/- 0.10 mS, respectively. The mean amplitude was significantly lower in the obesity, male, and total thyroidectomy (TT) groups. As body mass index (BMI) and age increased, the amplitude of EMG tended to decrease significantly.Conclusions: The evoked amplitude recorded with the skin electrodes was relatively low. A larger surgical extent, obesity, male sex, and age >55 years showed significantly lower evoked amplitudes