Open adsorption system for atmospheric CO2 capture: Scaling and sensitivity analysis
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- Nature IndexSCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- ENERGY294 · 2024
- 피인용
- Web of Science 12Scopus 13
- FWCI (Scopus)
- 1.06
- JCR IF
- JCR 2023 9
- ISSN
- 0360-5442
저자
- Liu, Xuetao제1저자Kyushu Univ, Fac Engn Sci, Dept Adv Environm Sci & Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
- Saren, SagarKyushu Univ, Fac Engn Sci, Dept Adv Environm Sci & Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
- Chen, HaonanKyushu Univ, Fac Engn Sci, Dept Adv Environm Sci & Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
- 정지환Pusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
- Li, Minxia교신저자Tianjin Univ, Key Lab Efficient Utilizat Low & Medium Grade Ener, Minist Educ China, Tianjin 300072, Peoples R China
- Dang, ChaobinUniv Fukui, Sch Engn, Fukui 9108507, Japan
- Miyazaki, TakahikoKyushu Univ, Fac Engn Sci, Dept Adv Environm Sci & Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
- Thu, Kyaw교신저자Kyushu Univ, Fac Engn Sci, Dept Adv Environm Sci & Engn, Kasuga Koen 6-1, Kasuga, Fukuoka 8168580, Japan
초록
Open adsorption process of gas mixtures involves complex heat and mass transfer mechanisms. Understanding of the physical mechanisms and their impacts on the adsorption process from gas mixtures is vital. In this study, a detailed analysis of an open CO2 adsorption from CO2/N2 mixtures using zeolite 13X-APG was investigated. Key physical mechanisms (unsteady, diffusive, convective, and component source, etc.) involved were scrutinized, and their order of magnitudes relative to the system energy complex were determined. The influences of these physical mechanisms on the equilibrium and dynamic nature throughout the capture were quantified. The validated computational fluid dynamics (CFD) simulations for the same adsorption domain were carried out to verify the rationality of the scaling method. The adsorption time, tad; the maximum average temperature, T‾max; CO2 removal rate, Rre,CO2; equilibrium pressure drop, ΔPeq on different scale parameters and their sensitivity were investigated. The maximum relative sensitivity to porosity was found to be −0.945, 0.0235, −0.357, and −5.33 for tad, T‾max, Rre,CO2 and ΔPeq, respectively. It is observed that heat transfer by the conduction mechanism inside the bed significantly influences all scale parameters, except for ΔPeq. This work will contribute to a better understanding of the atmospheric CO2 adsorption and provide guidance for the design optimization.
키워드
CO2 captureOpen adsorptionProcess analysisScaling analysisSensitivity analysisVACUUM SWING ADSORPTIONFIXED-BED ADSORPTIONDIRECT AIR CAPTURECARBON-DIOXIDENITROGENTSAOPTIMIZATIONMIXTURECOEFFICIENTSSIMULATION
식별자
- Scopus EID
- 2-s2.0-85187208324
- WoS UID
- 001203174400001



로그인
연구물 목록으로