본문 바로가기

Liquid-metal-based three-dimensional microelectrode arrays integrated with implantable ultrathin retinal prosthesis for vision restoration

문서 유형
연구출판물 · 학술지 논문
등재
Nature IndexSCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
NATURE NANOTECHNOLOGY19(5) · pp.688 · 2024
피인용
Web of Science 127Scopus 126
FWCI (Scopus)
12.56
JCR IF
JCR 2023 38.1
ISSN
1748-3387

저자

  1. Chung, Won Gi제1저자Yonsei Univ, Dept Mat Sci & Engn, Seoul, South Korea
  2. Jang, JiukYonsei Univ, Dept Mat Sci & Engn, Seoul, South Korea
  3. Cui, GangYonsei Univ, Severance Eye Hosp, Inst Vis Res, Dept Ophthalmol,Coll Med, Seoul, South Korea
  4. Lee, SanghoonYonsei Univ, Dept Mat Sci & Engn, Seoul, South Korea
  5. Jeong, HanYonsei Univ, Severance Eye Hosp, Inst Vis Res, Dept Ophthalmol,Coll Med, Seoul, South Korea
  6. 강혜수Pusan Natl Univ, Sch Chem Engn, Busan, South Korea
  7. Seo, HunkyuYonsei Univ, Dept Mat Sci & Engn, Seoul, South Korea
  8. Kim, SuminYonsei Univ, Dept Mat Sci & Engn, Seoul, South Korea
  9. Kim, EnjiYonsei Univ, Dept Mat Sci & Engn, Seoul, South Korea
  10. Lee, JunwonYonsei Univ, Gangnam Severance Hosp, Inst Vis Res, Dept Ophthalmol,Coll Med, Seoul, South Korea
  11. 이승걸교신저자Pusan Natl Univ, Sch Chem Engn, Busan, South Korea
  12. Byeon, Suk Ho교신저자Yonsei Univ, Severance Eye Hosp, Inst Vis Res, Dept Ophthalmol,Coll Med, Seoul, South Korea
  13. Park, Jang-Ung교신저자Yonsei Univ, Dept Mat Sci & Engn, Seoul, South Korea

초록

Electronic retinal prostheses for stimulating retinal neurons are promising for vision restoration. However, the rigid electrodes of conventional retinal implants can inflict damage on the soft retina tissue. They also have limited selectivity due to their poor proximity to target cells in the degenerative retina. Here we present a soft artificial retina (thickness, 10 μm) where flexible ultrathin photosensitive transistors are integrated with three-dimensional stimulation electrodes of eutectic gallium–indium alloy. Platinum nanoclusters locally coated only on the tip of these three-dimensional liquid-metal electrodes show advantages in reducing the impedance of the stimulation electrodes. These microelectrodes can enhance the proximity to the target retinal ganglion cells and provide effective charge injections (72.84 mC cm−2) to elicit neural responses in the retina. Their low Young’s modulus (234 kPa), owing to their liquid form, can minimize damage to the retina. Furthermore, we used an unsupervised machine learning approach to effectively identify the evoked spikes to grade neural activities within the retinal ganglion cells. Results from in vivo experiments on a retinal degeneration mouse model reveal that the spatiotemporal distribution of neural responses on their retina can be mapped under selective localized illumination areas of light, suggesting the restoration of their vision.

키워드

STIMULATIONIMPEDANCE

식별자

Scopus EID
2-s2.0-85182462535
WoS UID
001142543100003