본문 바로가기

Feasibility of a deep learning artificial intelligence model for the diagnosis of pediatric ileocolic intussusception with grayscale ultrasonography

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q2Scopus Q2KCI Q1
저널
ULTRASONOGRAPHY43(1) · pp.57 · 2024
피인용
Web of Science 7Scopus 9KCI 0
FWCI (Scopus)
1.42
JCR IF
JCR 2023 2.4
ISSN
2288-5919

저자

  1. Kim, Se Woo제1저자Seoul Natl Univ Hosp, Dept Radiol, Seoul, South Korea
  2. 천정은교신저자Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
  3. 최영훈Seoul Natl Univ, Childrens Hosp, Dept Radiol, Seoul, South Korea
  4. 황재연Pusan Natl Univ, Yangsan Hosp, Dept Radiol, Yangsan, South Korea
  5. Shin, Su-MiSeoul Natl Univ, Seoul Metropolitan Govt Boramae Med Ctr, Dept Radiol, Seoul, South Korea
  6. Cho, Yeon JinSeoul Natl Univ, Childrens Hosp, Dept Radiol, Seoul, South Korea
  7. Lee, SeunghyunSeoul Natl Univ, Childrens Hosp, Dept Radiol, Seoul, South Korea
  8. Lee, Seul BiSeoul Natl Univ, Childrens Hosp, Dept Radiol, Seoul, South Korea

초록

Purpose: This study explored the feasibility of utilizing a deep learning artificial intelligence (AI) model to detect ileocolic intussusception on grayscale ultrasound images.Methods: This retrospective observational study incorporated ultrasound images of children who underwent emergency ultrasonography for suspected ileocolic intussusception. After excluding video clips, Doppler images, and annotated images, 40,765 images from two tertiary hospitals were included (positive-to-negative ratio: hospital A, 2,775:35,373; hospital B, 140:2,477). Images from hospital A were split into a training set, a tuning set, and an internal test set (ITS) at a ratio of 7:1.5:1.5. Images from hospital B comprised an external test set (ETS). For each image indicating intussusception, two radiologists provided a bounding box as the ground-truth label. If intussusception was suspected in the input image, the model generated a bounding box with a confidence score (0-1) at the estimated lesion location. Average precision (AP) was used to evaluate overall model performance. The performance of practical thresholds for the modelgenerated confidence score, as determined from the ITS, was verified using the ETS.Results: The AP values for the ITS and ETS were 0.952 and 0.936, respectively. Two confidence thresholds, CT<sub>opt</sub> and CT<sub>precision</sub>, were set at 0.557 and 0.790, respectively. For the ETS, the perimage precision and recall were 95.7% and 80.0% with CT<sub>opt</sub>, and 98.4% and 44.3% with CT<sub>precision</sub>. For per-patient diagnosis, the sensitivity and specificity were 100.0% and 97.1% with CT<sub>opt</sub>, and 100.0% and 99.0% with CT<sub>precision</sub>. The average number of false positives per patient was 0.04 with CT<sub>opt</sub> and 0.01 for CT<sub>precision</sub>.Conclusion: The feasibility of using an AI model to diagnose ileocolic intussusception on ultrasonography was demonstrated. However, further study involving bias-free data is warranted for robust clinical validation.

키워드

IntussusceptionUltrasoundDeep learningArtificial intelligencePediatric emergency medicineCHILDHOOD INTUSSUSCEPTION