본문 바로가기

Femoral artery collapse ratio as an indicator of chest compression quality during cardiopulmonary resuscitation in a porcine cardiac arrest model

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q4Scopus Q3
저널
SIGNA VITAE19(6) · pp.67 · 2023
피인용
Web of Science 4Scopus 4
FWCI (Scopus)
0.56
JCR IF
JCR 2022 1.1
ISSN
1334-5605

저자

  1. 민문기제1저자Pusan Natl Univ, Sch Med, Dept Emergency Med, Busan 50612, South Korea
  2. 이대섭Pusan Natl Univ, Sch Med, Dept Emergency Med, Busan 50612, South Korea
  3. 이민지Pusan Natl Univ, Sch Med, Dept Emergency Med, Busan 50612, South Korea
  4. 천모세Pusan Natl Univ, Sch Med, Dept Emergency Med, Busan 50612, South Korea
  5. 손승우Pusan Natl Univ, Sch Med, Dept Emergency Med, Busan 50612, South Korea
  6. 현태규Pusan Natl Univ, Sch Med, Dept Emergency Med, Busan 50612, South Korea
  7. 류지호교신저자Pusan Natl Univ, Sch Med, Dept Emergency Med, Busan 50612, South Korea

초록

Cardiopulmonary resuscitation (CPR) quality is crucial for improving patient survival rates after cardiac arrest. This study aimed to investigate the usefulness of femoral artery collapse ratio (systolic diameter/diastolic diameter ratio) measurement using M-mode ultrasound versus end-tidal carbon dioxide (ETCO2) for the assessment of high-quality CPR in a porcine cardiac arrest model. A total of 10 male mongrel pigs (age range, 16–20 weeks; weight, 45–50 kg) were used. After anesthesia, the carotid artery was dissected and exposed. The animals were instrumented with an arterial catheter in the exposed carotid artery to monitor arterial blood pressure. Cardiac arrest was induced by injecting potassium chloride (KCl, 40 equivalents of weight). The animals underwent chest compression using a mechanical device, and the chest compression depth and ETCO2 were measured using a defibrillator. To obtain hemodynamic information, two investigators performed an ultrasound examination on both femoral arteries. One examiner measured the femoral peak systolic velocity (PSV), while the other measured the diameters of the femoral artery (systolic diameter and diastolic diameter) in a transverse or longitudinal position using the M-mode of the linear ultrasound probe. As the compression depth increased, ETCO2, femoral artery diameter, collapse ratio (systolic diameter/diastolic diameter), and blood flow increased; however, PSV decreased. The ETCO2 and collapse ratio were positively correlated. The femoral artery collapse ratio, measured using the M-mode ultrasound, could be an alternative and simple method to evaluate high-quality CPR.