본문 바로가기

전자 미트 응용을 위한 유연 압전 충격 센서의 제조와 특성 평가

Fabrication and Evaluation of a Flexible Piezoelectric Impact Force Sensor for Electronic Mitt Application

문서 유형
연구출판물 · 학술지 논문
등재
KCIScopus
저널
센서학회지28(2) · pp.106 · 2019
피인용
Scopus 0KCI 0
FWCI (Scopus)
0
ISSN
1225-5475

저자

  1. 나용현제1저자Department of Materials Science and Engineering, Pusan National University, Engineering Building #2, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Korea
  2. Lee, Min-SeonOptic&electronic Components Materials Center, Korea Institute of Ceramic Engineering and Technology, 101, soho-ro, Jinju-si, Gyeongsangnam-do, 52851, Korea
  3. 조정호Optic&electronic Components Materials Center, Korea Institute of Ceramic Engineering and Technology, 101, soho-ro, Jinju-si, Gyeongsangnam-do, 52851, Korea
  4. Paik, Jong-HooOptic&electronic Components Materials Center, Korea Institute of Ceramic Engineering and Technology, 101, soho-ro, Jinju-si, Gyeongsangnam-do, 52851, Korea
  5. 이정우Department of Materials Science and Engineering, Pusan National University, Engineering Building #2, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Korea
  6. Park, YoungjunINI Tech R&D center, 109, soho-ro, Jinju-si, Gyeongsangnam-do, 52851, Korea
  7. Jeong, Young Hun교신저자Optic&electronic Components Materials Center, Korea Institute of Ceramic Engineering and Technology, 101, soho-ro, Jinju-si, Gyeongsangnam-do, 52851, Korea

초록

Flexible impact force sensors composed of piezoelectric PZT/PDMS composite sandwiched between Al/PET films were fabricated and their voltage signal characteristics were evaluated under varying impact forces for electronic mitt applications. The piezoelectric impact force sensor on an ethylene-vinyl acetate (EVA) substrate exhibited an output voltage difference of no greater than 40 mV a periodical impact test in with the impact load was increased by as much as 240 N by a restoration time of 5 s in a five-time experiment, implying good sensing ability. Moreover, the impact force sensor embedded four electronic mitts showed a reliable sensitivity of less than 1 mV/N and good repeatability under 100 N-impact force during a cycle test executed 10,000 times. This indicated that the fabricated flexible piezoelectric impact sensor could be used in electronic mitt applications. However, the relatively low elastic limit of substrate material such as EVA or poly-urethane slightly deteriorated the sensitivity of the impact sensor embedded electronic mitt at over 200 N-impact forces.

키워드

CompositeElectronic mittFlexible sensorImpact force sensorPiezoelectric

식별자

Scopus EID
2-s2.0-85174626161
KCI
ART002453886