본문 바로가기

A High-Performance Liquid Chromatography with Photodiode Array Detection Method for Simultaneous Determination of Three Compounds Isolated from Wikstroemia ganpi: Assessment of the Effects on Cytochrome P450-Mediated Metabolism In Vitro and In Vivo

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
NUTRIENTS15(18) · #4061 · 2023
피인용
Web of Science 5Scopus 7
FWCI (Scopus)
0.61
JCR IF
JCR 2022 5.9
ISSN
2072-6643

저자

  1. 김민지제1저자Pusan Natl Univ, Res Inst Drug Dev, Busan 46241, South Korea
  2. 서성욱Pusan Natl Univ, Coll Pharm, Dept Mfg Pharm, Busan 46241, South Korea
  3. 김태영Pusan Natl Univ, Coll Pharm, Dept Mfg Pharm, Busan 46241, South Korea
  4. 조범근Pusan Natl Univ, Res Inst Drug Dev, Busan 46241, South Korea
  5. Kim, Su-NamKorea Inst Sci & Technol, Nat Prod Res Ctr, Kangnung 25451, South Korea
  6. 윤인수교신저자Pusan Natl Univ, Coll Pharm, Dept Mfg Pharm, Busan 46241, South Korea
  7. 양민혜교신저자Pusan Natl Univ, Res Inst Drug Dev, Busan 46241, South Korea

초록

In natural products, the content and quality of the marker components differ depending on the part, production area, collection period, and extraction method; therefore, a standardized analysis method is required to obtain consistent results. This study developed a simultaneous analysis method for three marker components (7-methoxylutolin-5-O-glucoseide, pilloin 5-O-beta-d-glucopyranoside, rutarensin) isolated and purified from Wikstroemia ganpi (W. ganpi). Simultaneous analysis was performed using high-performance liquid chromatography with photodiode array detection (HPLC-PDA) method that was validated according to the International Council for Harmonisation (ICH) guidelines. The developed analytical method exhibited linearity (r(2) > 0.999), detection limits (0.72-3.34 mu g/mL), and quantification limits (2.19-10.22 mu g/mL). The relative standard deviation (RSD) value of intra- and inter-day precisions was less than 1.68%, and analyte recoveries (93.42-117.55%; RSD < 1.86%) were validated according to the analytical procedures, and all parameters were within the allowable range. Quantitative analysis of the three marker components from W. ganpi MeOH extract (WGM) showed 7-methoxylutolin-5-O-glucoseide with the highest content (51.81 mg/g). The inhibitory effects of WGM on cytochrome P450 (CYP) substrate drugs were further investigated. The in vitro study revealed that WGM inhibited the CYP3A-mediated metabolism of buspirone and that 7-methoxylutolin-5-O-glucoseide and pilloin 5-O-beta-d-glucopyranoside inhibited the metabolism of buspirone with IC50 values of 2.73 and 18.7 mu M, respectively. However, a single oral dose of WGM did not have significant effects on the pharmacokinetics of buspirone in rats, suggesting that WGM cannot function as an inhibitor of CYP3A-mediated metabolism in vivo.

키워드

Wikstroemia ganpi7-methoxylutolin-5-O-glucoseideherb-drug interactionHPLC-PDApharmacokineticspilloin 5-O-beta-d-glucopyranosiderutarensinvalidationAGENTSANTIOXIDANTBIOACTIVITYINHIBITIONANTICANCERROOTSSTEMS

식별자

Scopus EID
2-s2.0-85172272004
WoS UID
001079944200001