Realistic thermal analysis of the CANDU spent fuel dry storage canister
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q1Scopus Q1KCI Q2
- 저널
- NUCLEAR ENGINEERING AND TECHNOLOGY55(12) · pp.4597 · 2023
- 피인용
- Web of Science 5Scopus 5KCI 1
- FWCI (Scopus)
- 0.39
- JCR IF
- JCR 2022 2.7
- ISSN
- 1738-5733
저자
- 이태강제1저자Pusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
- Kim, TaehyeonKorea Hydro & Nucl Power Co Ltd, Cent Res Inst, Daejeon 305343, South Korea
- Na, TaehyungKorea Hydro & Nucl Power Co Ltd, Cent Res Inst, Daejeon 305343, South Korea
- 윤병조Pusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
- 정재준교신저자Pusan Natl Univ, Sch Mech Engn, Busan 46241, South Korea
초록
Thermal analysis of the CANDU spent fuel dry storage canister is very important to ensure the integrity of the spent fuel. The analyses have been conducted using a conservative approach, with a particular focus on the peak cladding temperature (PCT) of the fuel rods in the canister. In this study, we have performed a realistic thermal analysis using a computational fluid dynamics (CFD) code. The canister contains 9 fuel bundle baskets. A detailed analysis of even a single basket requires significant computational resources. To overcome this challenge, we replaced each basket with an equivalent heat conductor (EHC), of which effective thermal conductivity (ETC) is developed from the results of detailed CFD calculations of a fuel bundle basket. Then, we investigated the effects of some conservative models, ultimately aiming at a realistic analysis. The results revealed: (i) The influence of convective heat transfer in the basket cannot be ignored, but it's less significant than expected. (ii) Modeling of the lifting rod is crucial, as it plays a decisive role in axial heat transfer at the center of the canister and significantly reduces the PCT. (iii) Convection within the canister is very important, as it not only reduces the PCT but also shifts its location upwards.
키워드
CANDU spent fuelCFD codeDry storage canisterPeak cladding temperatureRealistic thermal analysis
식별자
- Scopus EID
- 2-s2.0-85170283995
- WoS UID
- 001127874500001
- KCI
- ART003017269



로그인
연구물 목록으로