수소 정제 시스템의 건조 타워 열전달 해석을 위한 응용 프로그램 코드 개발
Development of an Application Program Code for Dryer Tower of Heat Transfer Analysis in Hydrogen Purification System
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCI
- 저널 순위
- KCI Q1
- 저널
- 한국수소및신에너지학회논문집34(4) · pp.334 · 2023
- 피인용
- KCI 0
- ISSN
- 1738-7264
저자
초록
The purity of hydrogen finally purified in the hydrogen purification process system is greatly influenced by the uniformity of the purification temperature of the dry tower. A in-house code that can be easily used by field designers has been developed to predict the capacity of the appropriate heat source and the time to reach the temperature of the dry tower. A code was developed to predict unsteady heat transfer using Visual Basic for Applications. To verify the developed code, a grid independence test was performed, and finally, calculations were performed for two cases. In the first case, the time for the temperature of the heater jacket to reach 360℃ was about 1,400 seconds when the supply heat source was 1,000 W. And in the second case, the time for the temperature of the heater jacket to reach 360℃ was about 710 seconds when the supply heat source was 2,000 W. It was confirmed that the developed code well describes the actual test data of the regeneration process of adsorption and desorption, and it is judged that the code developed in the design process of various capacity systems will be effectively applied to the heat capacity calculation in the future.
키워드
HydrogenVisual Basic for ApplicationsAdsorptionDesorptionDryer tower수소비주얼 베이식 애플리케이션흡착탈착건조 타워