Fast-Embeddable Grooved Microneedles by Shear Actuation for Accurate Transdermal Drug Delivery
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- PHARMACEUTICS15(7) · 2023
- 피인용
- Web of Science 8Scopus 9
- FWCI (Scopus)
- 0.78
- JCR IF
- JCR 2022 5.4
- ISSN
- 1999-4923
저자
- 임상구제1저자Pusan Natl Univ, Life & Ind Convergence Inst, Dept Biomat Sci, BK21 Four Program, Miryang 50463, South Korea
- 성금용Pusan Natl Univ, Life & Ind Convergence Inst, Dept Biomat Sci, BK21 Four Program, Miryang 50463, South Korea
- 아카시 따마라팔리Pusan Natl Univ, Life & Ind Convergence Inst, Dept Biomat Sci, BK21 Four Program, Miryang 50463, South Korea
- 이혜선Pusan Natl Univ, Life & Ind Convergence Inst, Dept Biomat Sci, BK21 Four Program, Miryang 50463, South Korea
- Lee, SeungsooSNVIA Co Ltd, Hyowon Ind Cooperat Bldg, Busan 46241, South Korea
- 이산하Pusan Natl Univ, Life & Ind Convergence Inst, Dept Biomat Sci, BK21 Four Program, Miryang 50463, South Korea
- Kim, SeminSNVIA Co Ltd, Hyowon Ind Cooperat Bldg, Busan 46241, South Korea
- 양승윤교신저자Pusan Natl Univ, Life & Ind Convergence Inst, Dept Biomat Sci, BK21 Four Program, Miryang 50463, South Korea
초록
Percutaneous drug delivery using microneedles (MNs) has been extensively exploited to increase the transdermal permeability of therapeutic drugs. However, it is difficult to control the precise dosage with existing MNs and they need to be attached for a long time, so a more simple and scalable method is required for accurate transdermal drug delivery. In this study, we developed grooved MNs that can be embedded into the skin by mechanical fracture following simple shear actuation. Grooved MNs are prepared from hyaluronic acid (HA), which is a highly biocompatible and biodegradable biopolymer. By adjusting the aspect ratio (length:diameter) of the MN and the position of the groove, the MN tip inserted into the skin can be easily broken by shear force. In addition, it was demonstrated that it is possible to deliver the desired amount of triamcinolone acetonide (TCA) for alopecia areata by controlling the position of the groove structure and the concentration of TCA loaded in the MN. It was also confirmed that the tip of the TCA MN can be accurately delivered into the skin with a high probability (98% or more) by fabricating an easy-to-operate applicator to provide adequate shear force. The grooved MN platform has proven to be able to load the desired amount of a drug and deliver it at the correct dose.
키워드
drug deliveryembeddinggrooved microneedletriamcinolone acetonide (TCA)TRIAMCINOLONE-ACETONIDEDISSOLVING MICRONEEDLESBIOLOGICAL-ACTIVITYSUSTAINED-RELEASEALOPECIA-AREATAPATCH