Scanning accuracy of an intraoral scanner according to different inlay preparation designs
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q2
- 저널
- BMC ORAL HEALTH23(1) · #515 · 2023
- 피인용
- Web of Science 26Scopus 27
- FWCI (Scopus)
- 3.12
- JCR IF
- JCR 2022 2.9
- ISSN
- 1472-6831
저자
- 박예리제1저자Pusan Natl Univ, Sch Dent, Dept Conservat Dent, Yangsan, South Korea
- 김재훈Pusan Natl Univ, Dent Res Inst, Sch Dent, Dept Dent Educ,Dent & Life Sci Inst, Yangsan, South Korea
- 박정길Pusan Natl Univ, Dent Res Inst, Dept Conservat Dent, Dent & Life Sci Inst,Sch Dent, Geumo Ro 20,Mulgeum Eup, Yangsan 50612, South Korea
- 손성애교신저자Pusan Natl Univ, Dent Res Inst, Dept Conservat Dent, Dent & Life Sci Inst,Sch Dent, Geumo Ro 20,Mulgeum Eup, Yangsan 50612, South Korea
초록
BackgroundThe accuracy of intraoral scanning plays a crucial role in the workflow of computer-assisted design/computer-assisted manufacturing. However, data regarding scanning accuracy for inlay preparation designs are lacking. The purpose of this in vitro study was to evaluate the influence of the depth of the occlusal cavity and width of the gingival floor of the proximal box on the trueness and precision of intraoral scans for inlay restoration.MethodsArtificial teeth were used in this study. Four types of preparations for mesio-occlusal inlay were performed on each #36 artificial tooth depending on two different depths of the occlusal cavity (1 mm and 2 mm) and widths of the gingival floor of the proximal box (1.5 mm and 2.5 mm). Artificial teeth were scanned 10 times each with Cerec Primescan AC, and another scan was performed subsequently with a laboratory scanner as a reference (n = 10). Standard tessellation language files were analyzed using a three-dimensional analysis software program. Experimental data were analyzed using two-way analysis of variance and the Bonferroni multiple comparison test.ResultsThe narrow shallow group had significantly higher deviation values for trueness than the wide deep group (p < 0.05). The wide deep group had the lowest average deviation value for trueness and there was no significant difference between the narrow deep and wide shallow groups (p > 0.05). For the mean maximum positive deviation, the wide groups had significantly lower values than the narrow groups (p < 0.05). Trueness was affected by both the width and depth(p < 0.05), whereas the mean maximum positive deviation was affected by the width (p < 0.05). The mean maximum negative deviation was affected by all three factors (p < 0.05). Precision was affected by the depth and the interaction between the depth of the occlusal cavity and width of the gingival floor (p < 0.05).ConclusionsThe design of different inlay cavity configurations affected the accuracy of the digital intraoral scanner. The highest average deviation for trueness was observed in the narrow shallow group and the lowest in the wide deep group. With regard to precision, the narrow shallow group showed the lowest average deviation, and the narrow deep group showed highest value.
키워드
Inlay designsIntraoral scannerCADCAMAccuracyTruenessPrecisionIN-VITRODIGITAL IMPRESSION
식별자
- Scopus EID
- 2-s2.0-85165651915
- WoS UID
- 001034637400003



로그인
연구물 목록으로