본문 바로가기

Deep Learning-reconstructed Parallel Accelerated Imaging for Knee MRI

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q3
저널
CURRENT MEDICAL IMAGING20 · 2024
피인용
Web of Science 8Scopus 7
FWCI (Scopus)
1.07
JCR IF
JCR 2023 1.1
ISSN
1573-4056

저자

  1. 이상민제1저자Pusan Natl Univ Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Dept Orthoped, Yangsan, South Korea
  2. 김민우Pusan Natl Univ, Sch Biomed Convergence Engn, Coll Informat & BioMed Engn, Yangsan, South Korea
  3. 박찬규교신저자Pusan Natl Univ Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Dept Radiol, Yangsan, South Korea
  4. 이동언Pusan Natl Univ, Sch Biomed Convergence Engn, Coll Informat & BioMed Engn, Yangsan, South Korea
  5. Kim, Kang SooSiemens Healthineers Ltd, Seoul, South Korea
  6. 정희석Pusan Natl Univ Yangsan Hosp, Res Inst Convergence Biomed Sci & Technol, Dept Radiol, Yangsan, South Korea
  7. 최민혁Pusan Natl Univ Yangsan Hosp, Pusan Natl Univ, Dept Prevent & Occupat Environm Med, Yangsan, South Korea

초록

Background: Deep learning (DL) can improve image quality by removing noise from accelerated MRI. Objective: To compare the quality of various accelerated imaging applications in knee MRI with and without DL. Methods: We analyzed 44 knee MRI scans from 38 adult patients using the DL-reconstructed parallel acquisition technique (PAT) between May 2021 and April 2022. The participants underwent sagittal fat-saturated T2-weighted turbo-spin-echo accelerated imaging without DL (PAT-2 [2-fold parallel accelerated imaging], PAT-3, and PAT-4) and with DL (DL with PAT-3 [PAT-3DL] and PAT-4 [PAT-4DL]). Two readers independently evaluated subjective image quality (diagnostic confidence of knee joint abnormalities, subjective noise and sharpness, and overall image quality) using a 4-point grading system (1-4, 4=best). Objective image quality was assessed based on noise (noise power) and sharpness (edge rise distance). Results: The mean acquisition times for PAT-2, PAT-3, PAT-4, PAT-3DL, and PAT-4DL sequences were 2:55, 2:04, 1:33, 2:04, and 1:33 min, respectively. Regarding subjective image quality, PAT-3DL and PAT-4DL scored higher than PAT-2. Objectively, DL-reconstructed imaging had significantly lower noise than PAT-3 and PAT-4 (P <0.001), but the results were not significantly different from those for PAT-2 (P >0.988). Objective image sharpness did not differ significantly among the imaging combinations (P =0.470). The inter-reader reliability ranged from good to excellent (κ = 0.761–0.832). Conclusion: PAT-4DL imaging in knee MRI exhibits similar subjective image quality, objective noise, and sharpness levels compared with conventional PAT-2 imaging, with an acquisition time reduction of 47%.

키워드

Accelerated imagingDeep learningImage qualityKnee MRIMusculoskeletal radiologyNoiseParallel imagingSIMULTANEOUS MULTISLICE

식별자

Scopus EID
2-s2.0-85163832285
WoS UID
001085241200024