본문 바로가기

Clinical outcomes of transbronchial cryobiopsy using a 1.1-mm diameter cryoprobe for peripheral lung lesions-A prospective pilot study

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
RESPIRATORY MEDICINE217 · 2023
피인용
Web of Science 24Scopus 27
FWCI (Scopus)
2.5
JCR IF
JCR 2022 4.3
ISSN
0954-6111

저자

  1. 김수한제1저자Pusan Natl Univ, Sch Med, Dept Internal Med, Pusan, South Korea
  2. 목정하Pusan Natl Univ, Sch Med, Dept Internal Med, Pusan, South Korea
  3. 김새롬Pusan Natl Univ, Sch Med, Dept Internal Med, Pusan, South Korea
  4. 류완호Pusan Natl Univ, Sch Med, Dept Internal Med, Pusan, South Korea
  5. 조은정Pusan Natl Univ, Sch Med, Dept Internal Med, Pusan, South Korea
  6. 김미현Pusan Natl Univ, Sch Med, Dept Internal Med, Pusan, South Korea
  7. 이광하Pusan Natl Univ, Sch Med, Dept Internal Med, Pusan, South Korea
  8. 김기욱Pusan Natl Univ, Sch Med, Dept Internal Med, Pusan, South Korea
  9. 박혜경Pusan Natl Univ, Sch Med, Dept Internal Med, Pusan, South Korea
  10. 이민기Pusan Natl Univ, Sch Med, Dept Internal Med, Pusan, South Korea
  11. 엄중섭교신저자Pusan Natl Univ, Sch Med, Dept Internal Med, Pusan, South Korea

초록

Objectives: Transbronchial cryobiopsy (TBCB) is a novel technique for the diagnosis of peripheral lung lesions (PLLs). We aim to evaluate the clinical outcomes of TBCB using a new 1.1-mm diameter cryoprobe for the diagnosis of PLLs. Materials and methods: We performed a prospective observational pilot study on the diagnosis of PLLs (diameter ≤30 mm) by TBCB, using a 1.1-mm diameter cryoprobe with radial endobronchial ultrasound (RP-EBUS), virtual bronchoscopic navigation and fluoroscopy from December 2021 to July 2022. Primary outcome was the pathological diagnostic yield of TBCB, and secondary outcome was adverse event. Results: A total of 50 patients were enrolled (mean lesion size, 21 mm). TBCB was performed in 49 patients up to three times except for the one with “invisible” finding on RP-EBUS. The overall diagnostic yield of TBCB was 90% (45/50). There was no difference in the diagnostic yield between size (20 mm vs. 20–30 mm; 88% [22/25] vs. 92% [23/25]; P = 1.000), RP-EBUS findings (concentric vs. others; 97% [28/29] vs. 81% [17/21]; P = 0.148), and acute angle location (apical segment of both upper lobes vs. others; 92% [12/13] vs. 89% [33/37]; P = 1.000). The cumulative diagnostic yields of the first, second, and third TBCB were 82% (41/50), 88% (44/50), and 90% (45/50), respectively. Mild bleeding was developed in 56% (28/50), and moderate bleeding was found in 26% (13/50). Conclusion: TBCB using a 1.1-mm diameter cryoprobe is an effective, reasonable method for the diagnosis of PLLs regardless of its size, RP-EBUS finding, and anatomical location without serious complication. Trial registration: Clinical Trials.Gov (NCT05046093).

키워드

BronchoscopyCryobiopsyEndobronchial ultrasoundLung noduleVIRTUAL BRONCHOSCOPIC NAVIGATIONRADIAL ENDOBRONCHIAL ULTRASOUNDPULMONARY-LESIONSDIAGNOSTIC YIELDGUIDE SHEATHULTRASONOGRAPHYCANCER

식별자

Scopus EID
2-s2.0-85163466181
WoS UID
001036903700001