Numerical analysis on the critical current evaluation and the correction of no-insulation HTS coil
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- ESCIKCIScopus
- 저널 순위
- Scopus Q4KCI Q4
- 저널
- 한국초전도.저온논문지25(1) · pp.16 · 2023
- 피인용
- Scopus 2KCI 1
- FWCI (Scopus)
- 0.14
- JCR IF
- JCR 2022 0.3
- ISSN
- 1229-3008
저자
초록
The International Electrotechnical Commission (IEC) 61788-26:2020 provides guidelines for measuring the critical current of Rare-earth barium copper oxide (REBCO) tapes using two methods: linear ramp and step-hold methods. The critical current measurement criterion, 1 or 0.1 μV/cm of electric field from IEC 61788-26 has been normally applied to REBCO coils or magnets. No-insulation (NI) winding technique has many advantages in aspects of electrical and thermal stability and mechanical integrity. However, the leak current from the NI REBCO coil can cause distortion in critical current measurement due to the characteristic resistance which causes the radial current flow paths. In this paper, we simulated the NI REBCO coil by applying both linear ramp and step-hold methods based on a simplified equivalent circuit model. Using the circuit analysis, we analyzed and evaluated both methods. By using the equivalent circuit model, we can evaluate the critical current of the NI REBCO coil, resulting in an estimation error within 0.1%. We also evaluate the accuracy of critical current measurement using both the linear ramp and step-hold methods. The accuracy of the linear ramp method is influenced by the inductive voltage, whereas the accuracy of the step-hold method depends on the duration of the hold-time. An adequate hold time, typically 5 to 10 times the time constant (τ), makes the step-hold method more accurate than the linear ramp method.
키워드
식별자
- Scopus EID
- 2-s2.0-85162896649
- KCI
- ART002948119



로그인
연구물 목록으로