본문 바로가기

Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q3Scopus Q1KCI Q2
저널
JOURNAL OF ADVANCED PROSTHODONTICS15(3) · pp.155 · 2023
피인용
Web of Science 4Scopus 6KCI 0
FWCI (Scopus)
1.35
JCR IF
JCR 2022 2.6
ISSN
2005-7806

저자

  1. 배은빈제1저자Pusan Natl Univ, Dent Res Inst, Dent & Life Sci Inst, Sch Dent,Educ & Res Team Life Sci Dent,Dept Prosth, Yangsan, South Korea
  2. 조원탁Pusan Natl Univ, Dent Res Inst, Dent & Life Sci Inst, Sch Dent,Educ & Res Team Life Sci Dent,Dept Prosth, Yangsan, South Korea
  3. 박도현Pusan Natl Univ, Dent Res Inst, Dent & Life Sci Inst, Sch Dent,Educ & Res Team Life Sci Dent,Dept Prosth, Yangsan, South Korea
  4. 황수현Pusan Natl Univ, Dent Res Inst, Dent & Life Sci Inst, Sch Dent,Educ & Res Team Life Sci Dent,Dept Prosth, Yangsan, South Korea
  5. 이소현Pusan Natl Univ, Dent Res Inst, Dent & Life Sci Inst, Sch Dent,Educ & Res Team Life Sci Dent,Dept Prosth, Yangsan, South Korea
  6. 윤미정Pusan Natl Univ, Dent Res Inst, Dent & Life Sci Inst, Sch Dent,Educ & Res Team Life Sci Dent,Dept Prosth, Yangsan, South Korea
  7. 정창모Pusan Natl Univ, Dent Res Inst, Dent & Life Sci Inst, Sch Dent,Educ & Res Team Life Sci Dent,Dept Prosth, Yangsan, South Korea
  8. 허중보교신저자Pusan Natl Univ, Dent Res Inst, Dent & Life Sci Inst, Sch Dent,Educ & Res Team Life Sci Dent,Dept Prosth, Yangsan, South Korea

초록

PURPOSE. This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS. Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS. There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 μm but there was no statistically significant difference within the groups (P > .05). CONCLUSION. All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 μm in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown.

키워드

CAD-CAMZirconia crownFitnessTruenessSEATING FORCEINTERNAL FITCAD/CAM TECHNOLOGYFILM THICKNESSCLINICAL FITMARGINAL FITCEMENTCHAIRSIDEDISCREPANCIESADAPTATION

식별자

Scopus EID
2-s2.0-85165090923
WoS UID
001035360700006
KCI
ART002968570