A deep-learning method using single phantom to enhance megavoltage image quality for patient positioning in chest radiotherapy: a feasibility study
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q4Scopus Q3KCI Q4
- 저널
- JOURNAL OF THE KOREAN PHYSICAL SOCIETY83(1) · pp.72 · 2023
- 피인용
- Web of Science 2Scopus 2KCI 1
- FWCI (Scopus)
- 0.14
- JCR IF
- JCR 2022 0.6
- ISSN
- 0374-4884
저자
- 전호상제1저자Pusan Natl Univ, Dept Radiat Oncol, Yangsan Hosp, Yangsan, South Korea
- 김동운Pusan Natl Univ, Dept Radiat Oncol, Yangsan Hosp, Yangsan, South Korea
- 주지현Pusan Natl Univ, Dept Radiat Oncol, Sch Med, Yangsan, South Korea
- 기용간교신저자Pusan Natl Univ, Dept Radiat Oncol, Sch Med, Yangsan, South Korea
- 김원택Pusan Natl Univ, Dept Radiat Oncol, Sch Med, Yangsan, South Korea
- 박달Pusan Natl Univ Hosp, Dept Radiat Oncol, Pusan, South Korea
- 남지호Pusan Natl Univ Hosp, Dept Radiat Oncol, Pusan, South Korea
- 김동현Pusan Natl Univ, Dept Radiat Oncol, Sch Med, Yangsan, South Korea
초록
Image-guided radiation treatment (IGRT) is essential for verifying patient positioning during modern radiotherapy. Although megavoltage digital radiographs (MV-DR) are available on most therapeutic linear accelerators and can be used for checking treatment beam shapes, they are much inferior to kilovoltage digital radiographs (KV-DR) in terms of image quality. As it is generally challenging to obtain a well-aligned MV − KV training dataset of patients in clinical scenarios, there is a lack of sufficient information on the accuracy of KV-DR synthesized using supervised training. Therefore, we aimed to synthesize pseudo KV-DR (pKV-DR) from MV-DR using a training dataset developed with a single anthropomorphic chest phantom. The phantom was adopted to obtain MV − KV image pairs at various gantry angles because these image pairs of patients are highly difficult to acquire and exactly align with each other. A deep-learning model based on U-net architecture was trained with the phantom image pairs using the mean absolute error (MAE) and structure similarity (SSIM) indices as loss functions. The mean MAEs of MV-DR and pKV-DR against KV-DR as the ground truth were 0.1152 and 0.0169, respectively, and their mean SSIM values were 0.9693 and 0.9942, respectively. Finally, pKV-DR showed a relatively high image similarity to that of KV-DR with smaller MAE (14.7%) and higher SSIM (2.5%), compared with MV-DR. The image contrast was also improved by 37.1% in clinical cases. The proposed method is expected to enable the implementation of improved IGRT with high image quality of KV-DR level, even in clinics where MV-DR is only available.
키워드
Deep learningKilovoltage imageMegavoltage imagePatient setupRadiotherapy