A deep-learning method using single phantom to enhance megavoltage image quality for patient positioning in chest radiotherapy: a feasibility study

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q4Scopus Q3KCI Q4
저널
JOURNAL OF THE KOREAN PHYSICAL SOCIETY83(1) · pp.72 · 2023
피인용
Web of Science 2Scopus 2KCI 1
FWCI (Scopus)
0.14
JCR IF
JCR 2022 0.6
ISSN
0374-4884

저자

  1. 전호상제1저자Pusan Natl Univ, Dept Radiat Oncol, Yangsan Hosp, Yangsan, South Korea
  2. 김동운Pusan Natl Univ, Dept Radiat Oncol, Yangsan Hosp, Yangsan, South Korea
  3. 주지현Pusan Natl Univ, Dept Radiat Oncol, Sch Med, Yangsan, South Korea
  4. 기용간교신저자Pusan Natl Univ, Dept Radiat Oncol, Sch Med, Yangsan, South Korea
  5. 김원택Pusan Natl Univ, Dept Radiat Oncol, Sch Med, Yangsan, South Korea
  6. 박달Pusan Natl Univ Hosp, Dept Radiat Oncol, Pusan, South Korea
  7. 남지호Pusan Natl Univ Hosp, Dept Radiat Oncol, Pusan, South Korea
  8. 김동현Pusan Natl Univ, Dept Radiat Oncol, Sch Med, Yangsan, South Korea

초록

Image-guided radiation treatment (IGRT) is essential for verifying patient positioning during modern radiotherapy. Although megavoltage digital radiographs (MV-DR) are available on most therapeutic linear accelerators and can be used for checking treatment beam shapes, they are much inferior to kilovoltage digital radiographs (KV-DR) in terms of image quality. As it is generally challenging to obtain a well-aligned MV − KV training dataset of patients in clinical scenarios, there is a lack of sufficient information on the accuracy of KV-DR synthesized using supervised training. Therefore, we aimed to synthesize pseudo KV-DR (pKV-DR) from MV-DR using a training dataset developed with a single anthropomorphic chest phantom. The phantom was adopted to obtain MV − KV image pairs at various gantry angles because these image pairs of patients are highly difficult to acquire and exactly align with each other. A deep-learning model based on U-net architecture was trained with the phantom image pairs using the mean absolute error (MAE) and structure similarity (SSIM) indices as loss functions. The mean MAEs of MV-DR and pKV-DR against KV-DR as the ground truth were 0.1152 and 0.0169, respectively, and their mean SSIM values were 0.9693 and 0.9942, respectively. Finally, pKV-DR showed a relatively high image similarity to that of KV-DR with smaller MAE (14.7%) and higher SSIM (2.5%), compared with MV-DR. The image contrast was also improved by 37.1% in clinical cases. The proposed method is expected to enable the implementation of improved IGRT with high image quality of KV-DR level, even in clinics where MV-DR is only available.

키워드

Deep learningKilovoltage imageMegavoltage imagePatient setupRadiotherapy