Bio-Corrosion, Mechanical and Microstructural Properties of TiTaMoVZr High-Entropy Alloy Film on Ti–6Al–4V Substrate
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q1Scopus Q1KCI Q2
- 저널
- METALS AND MATERIALS INTERNATIONAL29(12) · pp.3575 · 2023
- 피인용
- Web of Science 15Scopus 15KCI 3
- FWCI (Scopus)
- 1.09
- JCR IF
- JCR 2022 3.5
- ISSN
- 1598-9623
저자
- Gashti, Milad제1저자Univ Tehran, Coll Engn, Sch Met & Mat Engn, POB, Tehran 111554563, Iran
- Aghdam, Rouhollah Mehdinavaz교신저자Univ Tehran, Coll Engn, Sch Met & Mat Engn, POB, Tehran 111554563, Iran
- Motallebzadeh, AmirKoc Univ, Koc Univ Surface Sci & Technol Ctr KUYTAM, Sariyer, TR-34450 Istanbul, Turkiye
- Asl, Farid GharibiKoc Univ, Koc Univ Surface Sci & Technol Ctr KUYTAM, Sariyer, TR-34450 Istanbul, Turkiye
- Soltani, RezaUniv Tehran, Coll Engn, Sch Met & Mat Engn, POB, Tehran 111554563, Iran
- Ashrafi, AliIsfahan Univ Technol, Dept Mat Sci & Engn, Esfahan, Iran
- Balaei, HassanUniv Tehran, Coll Engn, Sch Met & Mat Engn, POB, Tehran 111554563, Iran
- 라자짜데 알리레자Pusan Natl Uunivers, Sch Mat Sci & Engn, Busan 46241, South Korea
초록
In recent years, high entropy alloys (HEA) have gained much attention due to their high corrosion resistance and mechanical properties. As a target, a high entropy TiTaMoVZr alloy with a atomic ratio of 20% was cast. Following that, the Ti–6Al–4V substrate was coated using the radio frequency magnetron sputtering technique. This process took place at a temperature of 400˚C under two different atmospheres of argon and air. HEA thin films’ mechanical, biological, and corrosion properties were investigated. The biocompatibility of these films was evaluated by MTT (3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide) assay. Based on the results, these films formed an amorphous phase with a higher hardness than the substrate. Also, the wettability and roughness of the surface of the films were higher compared to the substrate, which improved cell viability and their adhesion to the films surface. Because of their chemical compositions and unique structures, the films were more corrosion resistant than Ti6Al4V substrates were obtained. SEM investigation showed that there were more cracks on the surface of non-oxide high entropy films compared to the high entropy oxide deposit. The oxide film had no visible cracks, and also the thickness of the oxide high entropy film was more significant than the non-oxide film, which resulted in improved corrosion properties. Also, the Polarization resistance of the non-oxide (176 × 104 Ω.cm2) and oxide (218 × 104 Ω.cm2) films increased compared to the substrate (324 × 103 Ω.cm2). Furthermore, the coated samples had higher Young’s modulus and nanohardness than Ti6Al4V samples. This was attributed to the amorphous structure and the absence of defects such as dislocations and slip planes in the coating. Cell viability was improved for coated samples, however, atmospheric change in coating conditions did not significantly affect this cell viability. Graphical Abstract: [Figure not available: see fulltext.].
키워드
BiocompatibilityCorrosionHigh entropy alloyRF magnetronThin filmTiTaMoVZrIMPLANTS