Experimental study on pressure characteristics and flow coefficient of butterfly valve
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q2Scopus Q1KCI Q4
- 저널
- International Journal of Naval Architecture and Ocean Engineering15 · #ART002952695 · 2023
- 피인용
- Web of Science 27Scopus 28KCI 1
- FWCI (Scopus)
- 1.91
- JCR IF
- JCR 2022 2.2
- ISSN
- 2092-6782
저자
- 응우옌 꽝 카이제1저자Pusan Natl Univ, Dept Naval Architecture & Ocean Engn, Pusan, South Korea
- 정광효교신저자Pusan Natl Univ, Dept Naval Architecture & Ocean Engn, Pusan, South Korea
- 이강남Pusan Natl Univ, Dept Naval Architecture & Ocean Engn, Pusan, South Korea
- 박성부Pusan Natl Univ, Dept Naval Architecture & Ocean Engn, Pusan, South Korea
- 김종무Pusan Natl Univ, Dept Naval Architecture & Ocean Engn, Pusan, South Korea
- Suh, Sung BuDong Eui Univ, Dept Naval Architecture & Ocean Engn, Pusan, South Korea
- Lee, JaeyongDong Eui Univ, Dept Naval Architecture & Ocean Engn, Pusan, South Korea
초록
Air entrainment and self-aeration flow are phenomena that can generate fluctuation in pressure and induce disadvantages in piping systems. In this study, the mechanism of air bubble formation in Partially Filled Pipe Flow (PFPF) is investigated through a series of experiments on a butterfly valve with flow visualization and pressure measurement. This paper provides a description of the formation of bubbles induced by a butterfly valve and analyzes the characteristics of the pressure and flow coefficient of the valve. The pressures at various locations on the pipeline adjacent to the valve were measured to compare with the positions recommended by the International Society of Automation standard. The results indicated that in PFPF, the differences in the pressure between measured points downstream are noticeable, notably at valve openings less than 50 . The bubbles created at the valve, which lead to the highly-disordered aerated flow downstream, might induce the differences. The pressure drop and the flow rate across the butterfly valve in 100% water fraction flow are respectively 3e7.5 and 2e9 times higher than those in 90% WF. The flow coefficient of the 3-inch butterfly valve was found to increase linearly with the Reynolds number before leveling off when the Reynolds number exceeds 6 104. Besides, the flow coefficients in 100% water fraction flow are double those in 90% water fraction flow.
키워드
Butterfly valveFlow coefficientAir entrainmentBubble formationAerated flowWater fractionPARTIALLY-FILLED PIPESPERFORMANCE
식별자
- Scopus EID
- 2-s2.0-85153523594
- WoS UID
- 000982627800001
- KCI
- ART002952695



로그인
연구물 목록으로