Effect from Autoclave Sterilization and Usage on the Fracture Resistance of Heat-Treated Nickel-Titanium Rotary Files
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q2
- 저널
- MATERIALS16(6) · #2261 · 2023
- 피인용
- Web of Science 8Scopus 11
- FWCI (Scopus)
- 0.79
- JCR IF
- JCR 2022 3.4
- ISSN
- 1996-1944
저자
- El Abed, Rashid제1저자Mohammed Bin Rashid Univ Med & Hlth Sci, Hamdan Bin Mohammed Coll Dent Med, Endodont Dept, Dubai 505055, U Arab Emirates
- Al Raeesi, DanaEmirates Hlth Serv Estab, Endodont Dept, Dubai, U Arab Emirates
- Alshehhi, AishaMohammed Bin Rashid Univ Med & Hlth Sci, Hamdan Bin Mohammed Coll Dent Med, Endodont Dept, Dubai 505055, U Arab Emirates
- Alkhatib, ZuhairMohammed Bin Rashid Univ Med & Hlth Sci, Hamdan Bin Mohammed Coll Dent Med, Endodont Dept, Dubai 505055, U Arab Emirates
- Khamis, Amar H.Mohammed Bin Rashid Univ Med & Hlth Sci, Hamdan Bin Mohammed Coll Dent Med, Biostat Dept, Dubai 505055, U Arab Emirates
- Jamal, MohamedMohammed Bin Rashid Univ Med & Hlth Sci, Hamdan Bin Mohammed Coll Dent Med, Endodont Dept, Dubai 505055, U Arab Emirates
- 김현철교신저자Pusan Natl Univ, Dent Res Inst, Sch Dent, Dept Conservat Dent, Yangsan 50612, South Korea
초록
This study aimed to assess the effect of mechanical loading and heating on the cyclic fatigue and torsional fracture resistances of heat-treated nickel-titanium files after usage and autoclaving. Sixty files (One Curve) were tested for cyclic fatigue and torsional fracture resistances using customized devices. The files were divided into three groups according to the test conditions (n = 10); new (group-N), used for simulated canal shaping (group-U), and sterilized after use (group-S). For cyclic fatigue resistances, the files were freely rotated in a curved metal canal under body temperature; the time elapsed to fracture was recorded and the numbers of cycles to fracture (NCF) were calculated. For the torsional resistances, the file tip was fixed and rotated until the file fractured. The maximum torsional load and distortion angle were recorded. The toughness was calculated. Fracture fragments were examined with a scanning electron microscope. Data were analyzed using a one-way analysis of variance and Tukey's post hoc test at the significance level of 95%. Group-U showed significantly higher NCF than group-S (p < 0.05). However, there was no significant differences between groups-N and -S in the NCF (p > 0.05). Group-N showed a significantly bigger distortional angle and higher torsional toughness than groups-U and -S, but the ultimate torsional strength did not have significant difference between the groups. Under the limitation of this study, autoclave sterilization after single-usage did not improve the fracture resistance of heat-treated One Curve nickel-titanium files.
키워드
autoclave sterilizationdynamic fatiguefracture resistanceheat treatmentnickel-titanium filetorsional strengthCYCLIC FATIGUE RESISTANCEMECHANICAL-PROPERTIESTORSIONAL RESISTANCEBENDING PROPERTIESSHAPE-MEMORYINSTRUMENTS