Experimental study on seismic responses of tuned mass damper-applied real-scale piping system via shaking table tests
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- STRUCTURES50 · pp.1625 · 2023
- 피인용
- Web of Science 15Scopus 13
- FWCI (Scopus)
- 1.01
- JCR IF
- JCR 2022 4.1
- ISSN
- 2352-0124
저자
- Kwag, Shinyoung제1저자Hanbat Natl Univ, Dept Civil & Environm Engn, Daejeon 34158, South Korea
- Eem, Seunghyun교신저자Kyungpook Natl Univ, Dept Convergence & Fus Syst Engn, Sangju, South Korea
- Kwak, JinsungKorea Atom Energy Res Inst, 111 Daedeok Daero, Daejeon 34057, South Korea
- Lee, HwanhoKorea Atom Energy Res Inst, 111 Daedeok Daero, Daejeon 34057, South Korea
- Oh, JinhoKorea Atom Energy Res Inst, 111 Daedeok Daero, Daejeon 34057, South Korea
- Koo, Gyeong-HoiKorea Atom Energy Res Inst, 111 Daedeok Daero, Daejeon 34057, South Korea
- 장성진Pusan Natl Univ, Seism Res & Test Ctr, 49 Busandaehak Ro, Yangsan 50612, Gyeongnam, South Korea
- 전법규Pusan Natl Univ, Seism Res & Test Ctr, 49 Busandaehak Ro, Yangsan 50612, Gyeongnam, South Korea
초록
To secure the nuclear power plant (NPP) safety, it is essential to improve the seismic performance of piping systems. Accordingly, to achieve this purpose effectively, applying a tuned mass damper (TMD) to the NPP piping system has been attempted, but this is mostly limited to numerical analysis studies. Therefore, this study aimed to prove the TMD effect of reducing seismic responses of the real-scale NPP piping system through shaking table tests. As a result, it was confirmed that the TMD suppressed target and higher-order mode responses of the piping through the shaking table tests. In particular, the response control effects of the target mode and the higher-order mode were more pronounced when the earthquake motion intensity was larger. The application of the TMD showed reducing relative displacement responses in the harmonic motion excitation by about 80%-90%. This reduced peak relative displacement and normal stress responses by 33%-42% and 25%-37% on average, respectively, under random vibration excitation. Under the seismic excitation, peak relative displacement and normal stress responses were reduced by 7%-14% and 5%-27% on average, respectively. Finally, piping and piping-TMD finite element analysis models were successfully created and validated based on the shaking table test results.
키워드
Dynamic absorberPipingSeismic responseShaking table testTuned mass damperOPTIMIZATIONPARAMETERSVIBRATIONABSORBERDEVICESDESIGN
식별자
- Scopus EID
- 2-s2.0-85150898208
- WoS UID
- 000962013000001



로그인
연구물 목록으로