본문 바로가기

Dicarboxylate-containing and fully substituted ferrocene with rapid dissolvability, high solubility, good stability, and moderate formal potential for mediated electrochemical detection

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
JOURNAL OF MATERIALS CHEMISTRY B11(10) · pp.2258 · 2023
피인용
Web of Science 6Scopus 6
FWCI (Scopus)
0.31
JCR IF
JCR 2022 7
ISSN
2050-750X

저자

  1. 이우형제1저자Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
  2. 바티아 아만Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
  3. 포누사미 난다쿠마르Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
  4. 김경호Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
  5. 주정민교신저자Pusan Natl Univ, Dept Chem, Busan 46241, South Korea
  6. 양해식교신저자Pusan Natl Univ, Dept Chem, Busan 46241, South Korea

초록

An electron mediator with rapid dissolvability and high solubility in aqueous electrolyte solutions is essential for point-of-care testing based on mediated electrochemical detection. However, most ferrocenyl (Fc) compounds have slow dissolvability and poor solubility owing to high hydrophobicity of the Fc backbone. Moreover, many Fc compounds have poor stability and nonoptimal formal potential (). Herein, we present an Fc compound, Fc8m2c, which exhibits rapid dissolvability, high solubility, good stability, and moderate along with its high electron-mediation rate. The of Fc8m2c (0.17 V vs. Ag/AgCl) is tuned by two electron-withdrawing acyl substituents and eight electron-donating methyl substituents. Two pendant carboxylate groups of Fc8m2c allow for rapid dissolvability and high solubility (0.63 M in water), whereas full substitution in its two cyclopentadienyl ligands facilitates good chemical stability against decomposition in the presence of dissolved O2 and ambient light. A moderate enables the application of a potential of 0.07 V at which electrochemical background currents are low and also contributes toward resisting the decomposition of both Fc8m2c and Fc8m2c+. Fc8m2c provides a high electron-mediation rate constant (2.4 × 106 M−1 s−1) in glucose detection using glucose dehydrogenase. When Fc8m2c is applied to a glucose sensor, the calculated detection limit is ∼0.1 mM with a measurement period of 5 s. Considering that the normal concentration of glucose in serum is between 3.9 and 6.6 mM, the detection limit is sufficiently low. These results show that Fc8m2c is an excellent electron-mediator candidate for sensitive and rapid glucose detection.

키워드

SPIN-RESONANCE SPECTRAMOLECULAR-OXYGENOXIDATIONPHOTODECOMPOSITIONDECOMPOSITIONDERIVATIVESMECHANISM

식별자

Scopus EID
2-s2.0-85148770535
WoS UID
000944463300001