Effect of Measurement System Configuration and Operating Conditions on 2D Material-Based Gas Sensor Sensitivity
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- NANOMATERIALS13(3) · 2023
- 피인용
- Web of Science 13Scopus 16
- FWCI (Scopus)
- 0.88
- JCR IF
- JCR 2022 5.3
- ISSN
- 2079-4991
저자
- Ryu, Jongwon제1저자Korea Res Inst Stand & Sci, Adv Instrumentat Inst, Daejeon 34113, South Korea
- Shim, SeobKorea Res Inst Stand & Sci, Adv Instrumentat Inst, Daejeon 34113, South Korea
- Song, JeonginKorea Res Inst Stand & Sci, Adv Instrumentat Inst, Daejeon 34113, South Korea
- Park, JaeseoKorea Res Inst Stand & Sci, Adv Instrumentat Inst, Daejeon 34113, South Korea
- Kim, Ha SulChonnam Natl Univ, Dept Phys, Gwangju 61186, South Korea
- 이승기Pusan Natl Univ, Sch Mat Sci & Engn, Busan 46241, South Korea
- Shin, Jae CheolDongguk Univ, Div Elect & Elect Engn, Seoul 04620, South Korea
- Mun, Jihun교신저자Korea Res Inst Stand & Sci, Adv Instrumentat Inst, Daejeon 34113, South Korea
- Kang, Sang-Woo교신저자Korea Res Inst Stand & Sci, Adv Instrumentat Inst, Daejeon 34113, South Korea
초록
© 2023 by the authors.Gas sensors applied in real-time detection of toxic gas leakage, air pollution, and respiration patterns require a reliable test platform to evaluate their characteristics, such as sensitivity and detection limits. However, securing reliable characteristics of a gas sensor is difficult, owing to the structural difference between the gas sensor measurement platform and the difference in measurement methods. This study investigates the effect of measurement conditions and system configurations on the sensitivity of two-dimensional (2D) material-based gas sensors. Herein, we developed a testbed to evaluate the response characteristics of MoS2-based gas sensors under a NO2 gas flow, which allows variations in their system configurations. Additionally, we demonstrated that the distance between the gas inlet and the sensor and gas inlet orientation influences the sensor performance. As the distance to the 2D gas sensor surface decreased from 4 to 2 mm, the sensitivity of the sensor improved to 9.20%. Furthermore, when the gas inlet orientation was perpendicular to the gas sensor surface, the sensitivity of the sensor was the maximum (4.29%). To attain the optimum operating conditions of the MoS2-based gas sensor, the effects of measurement conditions, such as gas concentration and temperature, on the sensitivity of the gas sensor were investigated.
키워드
gas sensorsmeasurement systemstest platformstestbedtwo-dimensional materialsH2S SENSING CHARACTERISTICSROOM-TEMPERATUREHIGH RESPONSEGRAPHENE
식별자
- Scopus EID
- 2-s2.0-85147719154
- WoS UID
- 000929600500001



로그인
연구물 목록으로