본문 바로가기

Accuracy of Maxillary Positioning during Orthognathic Surgery: A Comparison of Web-based 3-Dimensional Virtual Surgical Planning and Actual Outcomes

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q4Scopus Q3
저널
JOURNAL OF CRANIOFACIAL SURGERY34(1) · pp.358 · 2023
피인용
Web of Science 2Scopus 2
FWCI (Scopus)
0.37
JCR IF
JCR 2022 0.9
ISSN
1049-2275

저자

  1. 남인혜제1저자Pusan Natl Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Yangsan, South Korea
  2. 마윤희Pusan Natl Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Yangsan, South Korea
  3. 자이스왈 엠 샤리야Pusan Natl Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Yangsan, South Korea
  4. Hwang, Jong-MinAllso Dent Clin, Seoul, South Korea
  5. 황대석교신저자Pusan Natl Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Yangsan, South Korea

초록

Copyright © 2022 Mutaz B. Habal, MD. All rights reserved.Purpose: To determine the accuracy of planned maxillary positioning by virtual surgery by comparing planned and actual postoperative outcomes. Materials and Methods: Twenty patients who underwent 2-jaw orthognathic surgery performed by a single surgeon from May 2017 to December 2020 were the subjects of this retrospective study. The coordinates of reference points in horizontal, sagittal, and coronal planes as determined by virtual surgery were compared with those of actual surgical outcomes. The reference points used were as follows: #16 mesiobuccal cusp tip (#16), #26 mesiobuccal cusp tip (#26), and #11 mesial tip (U1); anterior nasal spine; and posterior nasal spine. Three-dimensional linear distances between the reference point on which virtual surgery was performed and the reference point after the actual operation was calculated. Results: Of the 20 patients, there were 11 males and 9 females of average age 20.65 ± 2.41 years. Three-dimensional printed wafers had high accuracy with a maximum difference of 0.3 mm. No significant difference was observed in horizontal or coronal planes for any reference point, but a significant difference was observed in the sagittal plane. However, positional differences between planned and actual reference points were all <1 mm. Conclusions: Virtual surgical planning and 3-dimensional printed wafer achieved excellent maxillary positioning accuracies after orthognathic surgery.

키워드

3D printingCAD/CAMintermediate splintmaxillary positioningorthognathic surgery wafersplintvirtual surgical planning (VSP)MODEL SURGERYSIMULATIONALGORITHM

식별자

Scopus EID
2-s2.0-85145719395
WoS UID
000911295400102