본문 바로가기

Anodized screen-printed electrode modified with poly(5-amino-4H-1,2,4-triazole-3-thiol) film for ultrasensitive detection of Hg2+in fish samples

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 25Scopus 27
FWCI (Scopus)
1.64
JCR IF
JCR 2022 4.5
ISSN
1572-6657

저자

  1. 라마린감 마니칸단제1저자교신저자Pusan Natl Univ, Coll Nanosci & Nanotechnol, Dept Cogno Mechatron Engn, Busan 46241, South Korea
  2. Mani, S. PugalSaveetha Univ, Saveetha Dent Coll & Hosp, Saveetha Inst Med & Tech Sci SIMATS, Dept Orthodont, Chennai 600077, Tamil Nadu, India
  3. Selvan, Kumar SangeethaAnna Adarsh Coll Women, Dept Chem, Chennai 600040, Tamil Nadu, India
  4. Yoon, Jang-HeeKorea Basic Sci Inst, Busan Ctr, Busan 46742, South Korea
  5. 장승철교신저자Pusan Natl Univ, Coll Nanosci & Nanotechnol, Dept Cogno Mechatron Engn, Busan 46241, South Korea

초록

© 2022 Elsevier B.V.Anodized screen-printed electrode (ASPE) was modified by electrochemical polymerization of 5-amino-4H-1,2,4-triazole-3-thiol (ATT) to form a poly-ATT (PATT) film for the selective and sensitive detection of Hg2+ ions by Anodic Stripping Voltammetry (ASV). The porous PATT film was uniformly coated on the surface through disulfide (S–S) linkage, free N–H, and amide bonds for binding preconcentrated Hg2+ ions. The prepared PATT@ASPE was characterized by cyclic voltammetry, Field-Emission Scanning Electron Microscopy (FE-SEM), Transmission Electron Microscopy (TEM) with Energy Dispersive X-ray spectroscopy (EDS) and Attenuated Total Reflection Infrared Spectroscopy (ATR-IR). Under optimized experimental conditions (0.1 M KCl as supporting electrolyte and preconcentration at –0.1 V for 120 s), PATT@ASPE was successfully used for detecting Hg2+. A linear relationship between the anodic peak current and [Hg2+] was achieved in the concentration range of 0.03 to 245 nM, with a limit of detection (S/N = 3) of 0.005 nM and a calculated sensitivity of 15.0085 µA nM−1 L-1 cm−2. Further, selective detection of Hg2+ was demonstrated in the presence of interfering species such as other heavy metal ions (Pb2+, Cd2+, Cu2+, etc.), organic molecules, other cations, and various anions. The electroanalytical performance of PATT@ASPE exhibited outstanding long-term stability and reproducibility. Finally, PATT@ASPE was successfully applied to measure Hg2+ in fish muscle samples, and the results were validated using inductively coupled plasma-mass spectrometry.

키워드

Chemically modified electrodesElectrochemical detectionElectrochemical polymerizationFish musclesHg2+ICP-MSGLASSY-CARBON ELECTRODESTRIPPING VOLTAMMETRIC DETERMINATIONSOLID-PHASE EXTRACTIONELECTROCATALYTIC ACTIVITYMERCURYSENSORACIDHYPOXANTHINEGRAPHITEXANTHINE

식별자

Scopus EID
2-s2.0-85145651501
WoS UID
000918447200001