본문 바로가기

타이타늄 스크랩 충진복극과 SUS316 전극을 이용한 수용성 절삭유의 처리

Treatment of Soluble Cutting Fluid Using Titanium Scraps as Bipolar Packed Bed Electrolytic Device with SUS316 Electrode

문서 유형
연구출판물 · 학술지 논문
등재
KCI
저널 순위
KCI Q4
저널
한국환경기술학회지23(6) · pp.347 · 2022
피인용
KCI 0
ISSN
1229-8425

저자

  1. 박인수제1저자부산대학교
  2. 김고은교신저자부산대학교 바이오환경에너지학과
  3. 장성호부산대학교
  4. 유시현부산대학교 바이오환경에너지학과
  5. 송영채한국해양대학교
  6. 류재용경남대학교
  7. 박진식경운대학교

초록

In this study, the Ti scraps were used as bipolar packed-bed electrodes with SUS316 electrodes for treatment of soluble cutting fluid(SCF). The removal efficiency of CODCr from the SCF and oil and the Ti scraps were analysed in accordance with the Ti scrap density, current density, electrolyte type and concentration. The removal efficiency of CODCr after 60 min was 58.4 %, 56.2 %, 63.3 % and 60.3 % for a scrap density of 0, 10, 20 and 30 g/L, while the removal efficiency for oil was 61.8 %, 67.6 % and 65.3 % for a scrap density of 10, 20 and 30 g/L. In addition, the removal efficiency of CODCr after 60min was 63.3 %, 83.5 %, and 89.2 % and that of oil was 67.6 %, 79.8 % and 83.8 % for a current density 40, 60, and 80 A/m2. Finally, after testing the system with no electrolyte or with either Na2SO4 or NaCl (5-10 mM), the highest removal efficiency of CODCr and oil was 89.2 %, and 83.8 %, with no electrolyte and a current density of 80 A/m2. In conclusion, the removal of efficiency of CODCr and oil was maximized with a scrap density of 20 g/L, a current density of 80 A/m2, and non-electrolyte.

키워드

Titanium scrapsSoluble cutting fluidBipolarPacked bed electrolytic deviceSUS316 electrode.

식별자

KCI
ART002918768