본문 바로가기

Battery-Free, Wireless, Ionic Liquid Sensor Arrays to Monitor Pressure and Temperature of Patients in Bed and Wheelchair

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
SMALL19(9) · 2023
피인용
Web of Science 41Scopus 32
FWCI (Scopus)
1.8
JCR IF
JCR 2022 13.3
ISSN
1613-6810

저자

  1. Han, Hyeonseok제1저자Korea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea
  2. Oh, Yong SukChangwon Natl Univ, Dept Mech Engn, Chang Won 51140, South Korea
  3. Cho, SeokjooKorea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea
  4. Park, HyunwooKorea Adv Inst Sci & Technol, Sch Elect Engn, Daejeon 34141, South Korea
  5. Lee, Sung-UkKorea Atom Energy Res Inst, Adv 3D Printing Technol Dev Div, Daejeon 34057, South Korea
  6. Ko, KabseokKangwon Natl Univ, Dept Elect Engn, Chunchon 24341, South Korea
  7. Park, Jae-ManSeoul Natl Univ, Dept Mat Sci & Engn, Seoul 08826, South Korea
  8. Choi, JungrakKorea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea
  9. Ha, Ji-HwanKorea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea
  10. Han, ChankyuKorea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea
  11. Zhao, ZichenDalian Univ Technol, State Key Lab Struct Anal Ind Equipment, Dalian 116024, Peoples R China
  12. Liu, ZhuangjianAgcy Sci Technol & Res, Inst High Performance Comp, Singapore 138632, Singapore
  13. Xie, ZhaoqianDalian Univ Technol, State Key Lab Struct Anal Ind Equipment, Dalian 116024, Peoples R China
  14. Lee, Je-SangGimhae Hansol Rehabil & Convalescent Hosp, Dept Rehabil Med, Gimhae 50924, South Korea
  15. Min, Weon GiGimhae Hansol Rehabil & Convalescent Hosp, Dept Planning & Dev, Gimhae 50924, South Korea
  16. 이병주Pusan Natl Univ Hosp, Dept Rehabil Med, Busan 49241, South Korea
  17. Koo, JahyunKorea Univ, Sch Biomed Engn, Seoul 02841, South Korea
  18. Choi, Dong YunKorea Inst Ind Technol KITECH, Biomed Mfg Technol Ctr, Yeongcheon 38822, South Korea
  19. Je, MinkyuKorea Adv Inst Sci & Technol, Sch Elect Engn, Daejeon 34141, South Korea
  20. Sun, Jeong-YunSeoul Natl Univ, Dept Mat Sci & Engn, Seoul 08826, South Korea
  21. Park, Inkyu교신저자Korea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea

초록

© 2022 Wiley-VCH GmbH.Repositioning is a common guideline for the prevention of pressure injuries of bedridden or wheelchair patients. However, frequent repositioning could deteriorate the quality of patient's life and induce secondary injuries. This paper introduces a method for continuous multi-site monitoring of pressure and temperature distribution from strategically deployed sensor arrays at skin interfaces via battery-free, wireless ionic liquid pressure sensors. The wirelessly delivered power enables stable operation of the ionic liquid pressure sensor, which shows enhanced sensitivity, negligible hysteresis, high linearity and cyclic stability over relevant pressure range. The experimental investigations of the wireless devices, verified by numerical simulation of the key responses, support capabilities for real-time, continuous, long-term monitoring of the pressure and temperature distribution from multiple sensor arrays. Clinical trials on two hemiplegic patients confined on bed or wheelchair integrated with the system demonstrate the feasibility of sensor arrays for a decrease in pressure and temperature distribution under minimal repositioning.

키워드

battery-freeionic liquidspressure injuriespressure sensorswireless

식별자

Scopus EID
2-s2.0-85144306051
WoS UID