본문 바로가기

Copper laser patterning on a flexible substrate using a cost-effective 3D printer

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
SCIENTIFIC REPORTS12(1) · 2022
피인용
Web of Science 9Scopus 8
FWCI (Scopus)
0.22
JCR IF
JCR 2021 4.997
ISSN
2045-2322

저자

  1. 차크라보티 사잘제1저자Pusan Natl Univ, Inst Plast Informat & Energy Mat, Dept Chem Educ, Grad Dept Chem Mat, Busandaehakro 63-2, Busan 46241, South Korea
  2. 박호열Pusan Natl Univ, Inst Plast Informat & Energy Mat, Dept Chem Educ, Grad Dept Chem Mat, Busandaehakro 63-2, Busan 46241, South Korea
  3. 안성일교신저자Pusan Natl Univ, Inst Plast Informat & Energy Mat, Dept Chem Educ, Grad Dept Chem Mat, Busandaehakro 63-2, Busan 46241, South Korea

초록

© 2022, The Author(s).We studied the cost effective direct laser patterning of copper (Cu) on thin polyimide substrates (PI thickness: 12.5–50 µm) using a 405 nm laser module attached to an inexpensive 3D printer. The focal length of the laser was intentionally controlled to reduce defects on patterned Cu and surface damage of PI under predetermined process conditions. The appropriate focal length was examined at various focal distances. Focal distances of − 2.4 mm and 3 mm were found for the shorter focal length (SFL) and longer focal length (LFL), respectively, compared to the actual focal length. This resulted in clean Cu line patterns without line defects. Interestingly, the SFL case had a different Cu growth pattern to that of LFL, indicating that the small difference in the laser incident angle could affect Cu precursor sintering. Cu square patterns had a lower resistivity of 70 μΩ·cm for an LFL after three or four laser scans, while the SFL showed a resistivity below 48 μΩ·cm for a one-time laser scan. The residues of the Cu precursor on PI were easily removed with flowing water and normal surfactants. However, the resistivity of the patterns decreased after cleaning. Among the scan gaps, the Cu square pattern formed at a 70 μm scan gap had the lowest sheet resistance and the least change in resistance from around 4 to 4.4 Ω/ϒ after cleaning. This result implies that the adhesion of the patterned Cu could be improved if the coated Cu precursor was well sintered under the proper process conditions. For the application of this method to bioelectronics, including biosensors, LEDs were connected to the Cu patterns on PI attached to the arm skin and worked well, even when the substrate PI was bent during power connecting.

키워드

FABRICATIONELECTRODEINK

식별자

Scopus EID
2-s2.0-85143502203
WoS UID
000905463900076