본문 바로가기

Estimating tension of a prestressed concrete cable-stayed bridge under construction and traffic use conditions using a vision-based system

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
STRUCTURES47 · pp.299 · 2023
피인용
Web of Science 20Scopus 26
FWCI (Scopus)
2.02
JCR IF
JCR 2022 4.1
ISSN
2352-0124

저자

  1. 김성완제1저자Pusan Natl Univ, Seism Res & Test Ctr, 49 Busandaehak Ro, Yangsan 50612, Gyeongnam, South Korea
  2. 박동욱Pusan Natl Univ, Seism Res & Test Ctr, 49 Busandaehak Ro, Yangsan 50612, Gyeongnam, South Korea
  3. Kim, Jin-SooKorea Author Land & Infrastruct Safety, Honam Off, 3139 Dolsan Ro, Yeosu 59771, Jeonnam, South Korea
  4. Park, Jae-Bong교신저자Korea Author Land & Infrastruct Safety, Management Off, 24 Ena Ro,128 Beon Gil, Jinju 52856, Gyeongnam, South Korea

초록

© 2022 Institution of Structural EngineersIn cable-stayed bridges, cable is the primary member supporting the load, so cable tension is a very important factor in evaluating the integrity and safety of this type of bridge. The direct method of measuring the force of a cable using a load cell or hydraulic jack, and the indirect method of calculating the tension inversely using the shape condition of the cable and the measured dynamic characteristics are the most frequently used methods of measuring cable tension. In this study, cable tension was estimated using the indirect method. A vision-based system was also applied as a sensor to measure the cable's dynamic response. In order to improve the recognition of the control point during image analysis, the helical fillet of the cable was distinguished from the cable using mathematical morphology. A distorted image including a vehicle shows inaccurate results in image analysis due to the installation position of the vision-based system. Accordingly, the image including the vehicle was removed by calculating the similarity between the two images. In the cable-stayed bridge under construction, the tension measured in the lift-off test and the tension estimated by applying the vibration method showed an error of less than 3 %. The accuracy of the tension estimated using the vision-based system could be confirmed. In addition, when the tension measured in the existing cable-stayed bridge was compared with the tension measured during construction, the tension of the cable was confirmed to be well-maintained even after about 10 years of use.

키워드

Cable tensionCable-stayed bridgesIndirect methodVibration methodVision-based systemMATHEMATICAL MORPHOLOGYMONITORING-SYSTEMIMAGE-ANALYSISSENSORFORCEFATIGUEDESIGNFIELD

식별자

Scopus EID
2-s2.0-85142705498
WoS UID
000932743100002