본문 바로가기

Au Nanoparticle-Based Disposable Electrochemical Sensor for Detection of Leptospirosis in Clinical Samples

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q1
저널
ACS APPLIED NANO MATERIALS5(9) · pp.12454 · 2022
피인용
Web of Science 18Scopus 19
FWCI (Scopus)
0.75
JCR IF
JCR 2021 6.14
ISSN
2574-0970

저자

  1. Sapna, Kannan제1저자Deemed Univ, Yenepoya Res Ctr, Nanomat Res Lab NMRL, Nano Div, Mangalore 575018, India
  2. Sonia, Joseph
  3. 심윤보Pusan Natl Univ, Inst Biophysio Sensor Technol, Dept Chem, Pusan 46241, South Korea
  4. Arun, A. B.Yenepoya Deemed Univ, Yenepoya Res Ctr, Mangalore 575018, India
  5. Prasad, K. Sudhakara교신저자Deemed Univ, Yenepoya Res Ctr, Nanomat Res Lab NMRL, Nano Div, Mangalore 575018, India

초록

Leptospirosis is a worldwide zoonotic disease causing major health problems in tropical areas. A point-of-care test that is accurate for early diagnosis of leptospirosis is, thus, imperative and the need of the hour. Herein, we demonstrate the development of a disposable immunosensor based on gold nanoparticle (AuNp)-modified paper electrodes (PPEs) with carbon nanotube-labeled monoclonal anti-LipL32 (e-LipL32) for simple, rapid, and sensitive determination of Leptospira in clinical samples. The immunosensor was constructed on AuNp-decorated PPEs immobilized with self-assembled monolayers of glutathione for the incorporation of monoclonal antibodies specific to the leptospiral major outer membrane protein, LipL32. The e-LipL32 sensor was further characterized with scanning electron microscopy, X-ray photoelectron spectroscopy, and electrochemical techniques for demonstrating the robust formation of the sensor. The sensor exhibited a wide linear range up to 1 mu g/mL with an unprecedented low limit of detection of 348 fg/mL compared to the reported leptospirosis sensors to date. The sensor displayed acceptable precision, reproducibility, and long-term stability for LipL32 detection. Further, e-LipL32 was validated with 20 patient samples suspected of leptospirosis, including other febrile illnesses along with the gold standard macroscopic agglutination test, culture, IgM enzyme-linked immunosorbent assay, and IgM spot test. Based on the boxplot analysis of 20 patient samples, an average peak current above 9.8 mu A was classified as positive for leptospirosis. Compared to commercial diagnostic tools, our sensor provides rapid results and offers an alternative, specific, and sensitive method for early diagnosis of leptospirosis.

키워드

electrochemical immunosensorLipL32validationleptospirosisCNT-labeled antibodygold nanoparticles

식별자

Scopus EID
2-s2.0-85137279271
WoS UID
000848633800001