Emphysema Quantification Using Ultra-Low-Dose Chest CT: Efficacy of Deep Learning-Based Image Reconstruction

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q3Scopus Q2
저널
MEDICINA-LITHUANIA58(7) · #939 · 2022
피인용
Web of Science 24Scopus 22
FWCI (Scopus)
1.98
JCR IF
JCR 2021 2.948
ISSN
1010-660X

저자

  1. 염정아제1저자Pusan Natl Univ, Sch Med, Dept Radiol, Yangsan Hosp, Yangsan 50612, South Korea
  2. 김기욱Pusan Natl Univ Hosp, Dept Internal Med, Busan 49241, South Korea
  3. 황민희Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Radiol, Sch Med, Busan 49241, South Korea
  4. 이지원APusan Natl Univ, Pusan Natl Univ Hosp, Dept Radiol, Sch Med, Busan 49241, South Korea
  5. 김건일Pusan Natl Univ, Sch Med, Dept Radiol, Yangsan Hosp, Yangsan 50612, South Korea
  6. 송유선Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Radiol, Sch Med, Busan 49241, South Korea
  7. 이인숙Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Radiol, Sch Med, Busan 49241, South Korea
  8. 정연주교신저자Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Radiol, Sch Med, Busan 49241, South Korea

초록

Background and Objectives: Although reducing the radiation dose level is important during diagnostic computed tomography (CT) applications, effective image quality enhancement strategies are crucial to compensate for the degradation that is caused by a dose reduction. We performed this prospective study to quantify emphysema on ultra-low-dose CT images that were reconstructed using deep learning-based image reconstruction (DLIR) algorithms, and compared and evaluated the accuracies of DLIR algorithms versus standard-dose CT. Materials and Methods: A total of 32 patients were prospectively enrolled, and all underwent standard-dose and ultra-low-dose (120 kVp; CTDIvol < 0.7 mGy) chest CT scans at the same time in a single examination. A total of six image datasets (filtered back projection (FBP) for standard-dose CT, and FBP, adaptive statistical iterative reconstruction (ASIR-V) 50%, DLIR-low, DLIR-medium, DLIR-high for ultra-low-dose CT) were reconstructed for each patient. Image noise values, emphysema indices, total lung volumes, and mean lung attenuations were measured in the six image datasets and compared (one-way repeated measures ANOVA). Results: The mean effective doses for standard-dose and ultra-low-dose CT scans were 3.43 +/- 0.57 mSv and 0.39 +/- 0.03 mSv, respectively (p < 0.001). The total lung volume and mean lung attenuation of five image datasets of ultra-low-dose CT scans, emphysema indices of ultra-low-dose CT scans reconstructed using ASIR-V 50 or DLIR-low, and the image noise of ultra-low-dose CT scans that were reconstructed using DLIR-low were not different from those of standard-dose CT scans. Conclusions: Ultra-low-dose CT images that were reconstructed using DLIR-low were found to be useful for emphysema quantification at a radiation dose of only 11% of that required for standard-dose CT.

키워드

emphysemalow dose CTquantitative analysisdeep learningPULMONARY-FUNCTION TESTSCOMPUTED-TOMOGRAPHYOBJECTIVE QUANTIFICATIONITERATIVE RECONSTRUCTIONMORPHOMETRYDENSITY