Emphysema Quantification Using Ultra-Low-Dose Chest CT: Efficacy of Deep Learning-Based Image Reconstruction
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q3Scopus Q2
- 저널
- MEDICINA-LITHUANIA58(7) · #939 · 2022
- 피인용
- Web of Science 24Scopus 22
- FWCI (Scopus)
- 1.98
- JCR IF
- JCR 2021 2.948
- ISSN
- 1010-660X
저자
- 염정아제1저자Pusan Natl Univ, Sch Med, Dept Radiol, Yangsan Hosp, Yangsan 50612, South Korea
- 김기욱Pusan Natl Univ Hosp, Dept Internal Med, Busan 49241, South Korea
- 황민희Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Radiol, Sch Med, Busan 49241, South Korea
- 이지원APusan Natl Univ, Pusan Natl Univ Hosp, Dept Radiol, Sch Med, Busan 49241, South Korea
- 김건일Pusan Natl Univ, Sch Med, Dept Radiol, Yangsan Hosp, Yangsan 50612, South Korea
- 송유선Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Radiol, Sch Med, Busan 49241, South Korea
- 이인숙Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Radiol, Sch Med, Busan 49241, South Korea
- 정연주교신저자Pusan Natl Univ, Pusan Natl Univ Hosp, Dept Radiol, Sch Med, Busan 49241, South Korea
초록
Background and Objectives: Although reducing the radiation dose level is important during diagnostic computed tomography (CT) applications, effective image quality enhancement strategies are crucial to compensate for the degradation that is caused by a dose reduction. We performed this prospective study to quantify emphysema on ultra-low-dose CT images that were reconstructed using deep learning-based image reconstruction (DLIR) algorithms, and compared and evaluated the accuracies of DLIR algorithms versus standard-dose CT. Materials and Methods: A total of 32 patients were prospectively enrolled, and all underwent standard-dose and ultra-low-dose (120 kVp; CTDIvol < 0.7 mGy) chest CT scans at the same time in a single examination. A total of six image datasets (filtered back projection (FBP) for standard-dose CT, and FBP, adaptive statistical iterative reconstruction (ASIR-V) 50%, DLIR-low, DLIR-medium, DLIR-high for ultra-low-dose CT) were reconstructed for each patient. Image noise values, emphysema indices, total lung volumes, and mean lung attenuations were measured in the six image datasets and compared (one-way repeated measures ANOVA). Results: The mean effective doses for standard-dose and ultra-low-dose CT scans were 3.43 +/- 0.57 mSv and 0.39 +/- 0.03 mSv, respectively (p < 0.001). The total lung volume and mean lung attenuation of five image datasets of ultra-low-dose CT scans, emphysema indices of ultra-low-dose CT scans reconstructed using ASIR-V 50 or DLIR-low, and the image noise of ultra-low-dose CT scans that were reconstructed using DLIR-low were not different from those of standard-dose CT scans. Conclusions: Ultra-low-dose CT images that were reconstructed using DLIR-low were found to be useful for emphysema quantification at a radiation dose of only 11% of that required for standard-dose CT.
키워드
emphysemalow dose CTquantitative analysisdeep learningPULMONARY-FUNCTION TESTSCOMPUTED-TOMOGRAPHYOBJECTIVE QUANTIFICATIONITERATIVE RECONSTRUCTIONMORPHOMETRYDENSITY