Fast volumetric imaging with line-scan confocal microscopy by electrically tunable lens at resonant frequency
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- OPTICS EXPRESS30(11) · pp.19152 · 2022
- 피인용
- Web of Science 21Scopus 20
- FWCI (Scopus)
- 1.4
- JCR IF
- JCR 2021 3.833
- ISSN
- 1094-4087
저자
- Mac, Khuong Duy제1저자Gwangju Inst Sci & Technol, Dept Biomed Sci & Engn, Gwangju 61005, South Korea
- Qureshi, Muhammad MohsinPrincess Margaret Canc Ctr, Div Biophys & Bioimaging, Toronto, ON, Canada
- Na, MyeongsuSeoul Natl Univ, Dept Physiol & Biomed Sci, Coll Med, 103 Daehak Ro, Seoul 03080, South Korea
- Chang, SunghoeSeoul Natl Univ, Dept Physiol & Biomed Sci, Coll Med, 103 Daehak Ro, Seoul 03080, South Korea
- 엄태중Pusan Natl Univ, Dept Cogno Mechatron Engn, Busan 46241, South Korea
- Je, Hyunsoo ShawnDuke Natl Univ Singapore NUS, Signat Program Neurosci & Behav Disorders, Med Sch, 8 Coll Rd, Singapore 169857, Singapore
- Kim, Young RoMassachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
- Kwon, Hyuk-Sang교신저자Gwangju Inst Sci & Technol, Dept Biomed Sci & Engn, Gwangju 61005, South Korea
- Chung, EuiheonGwangju Inst Sci & Technol, Dept Biomed Sci & Engn, Gwangju 61005, South Korea
초록
© 2022 Optica Publishing GroupIn microscopic imaging of biological tissues, particularly real-time visualization of neuronal activities, rapid acquisition of volumetric images poses a prominent challenge. Typically, two-dimensional (2D) microscopy can be devised into an imaging system with 3D capability using any varifocal lens. Despite the conceptual simplicity, such an upgrade yet requires additional, complicated device components and usually suffers from a reduced acquisition rate, which is critical to properly document rapid neurophysiological dynamics. In this study, we implemented an electrically tunable lens (ETL) in the line-scan confocal microscopy (LSCM), enabling the volumetric acquisition at the rate of 20 frames per second with a maximum volume of interest of 315 × 315 × 80 µm3. The axial extent of point-spread-function (PSF) was 17.6 ± 1.6 µm and 90.4 ± 2.1 µm with the ETL operating in either stationary or resonant mode, respectively, revealing significant depth axial penetration by the resonant mode ETL microscopy. We further demonstrated the utilities of the ETL system by volume imaging of both cleared mouse brain ex vivo samples and in vivo brains. The current study showed a successful application of resonant ETL for constructing a high-performance 3D axially scanning LSCM (asLSCM) system. Such advances in rapid volumetric imaging would significantly enhance our understanding of various dynamic biological processes.
키워드
LIGHT-SHEET MICROSCOPYEXTENDED DEPTHIN-VIVOILLUMINATIONEXCITATIONPHASE
식별자
- Scopus EID
- 2-s2.0-85130501183
- WoS UID
- 000799725400118



로그인
연구물 목록으로