Development and Evaluation of the Utility of a Respiratory Monitoring and Visual Feedback System for Radiotherapy Using Machine Vision Technology
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- ESCIKCIScopus
- 저널 순위
- Scopus Q4KCI Q4
- 저널
- 방사선방어학회지47(1) · pp.8 · 2022
- 피인용
- Scopus 0KCI 0
- FWCI (Scopus)
- 0
- ISSN
- 2508-1888
저자
- 김철항제1저자Department of Biomedical Engineering, Pusan National University, Pusan, Korea;
- Choi, Hoon SikDepartment of Radiation Oncology, Gyeongsang National University Changwon Hospital, Gyeongsang National University College of Medicine, Changwon, Korea;
- Kang, Ki MunDepartment of Radiation Oncology, Gyeongsang National University Changwon Hospital, Gyeongsang National University College of Medicine, Changwon, Korea;
- Jeong, Bae KwonInstitute of Health Science, School of Medicine, Gyeongsang National University, Jinju, Korea;
- Jeong, HojinInstitute of Health Science, School of Medicine, Gyeongsang National University, Jinju, Korea;
- Ha, In BongInstitute of Health Science, School of Medicine, Gyeongsang National University, Jinju, Korea;
- Song, Jin Ho교신저자Institute of Health Science, School of Medicine, Gyeongsang National University, Jinju, Korea;
초록
Copyright © 2022 The Korean Association for Radiation ProtectionBackground: We developed a machine vision technology program that tracks patients’ real-time breathing and automatically analyzes their breathing patterns. Materials and Methods: To evaluate its potential for clinical application, the image tracking performance and accuracy of the program were analyzed using a respiratory motion phantom. Changes in the stability and regularity of breathing were observed in healthy adult volunteers according to whether the breathing pattern mirrored the breathing guidance. Results and Discussion: Displacement within a few millimeters was observed in real-time with a clear resolution, and the image tracking ability was excellent. This result was consistent even in the sections where breathing patterns changed rapidly. In addition, the respiratory gating method that reflected the individual breathing patterns improved breathing stability and regularity in all volunteers. Conclusion: The findings of this study suggest that this technology can be used to set the appropriate window and the range of internal target volume by reflecting the patient’s breathing pattern during radiotherapy planning. However, further studies in clinical populations are required to validate this technology.
키워드
Machine VisionRadiotherapyRespiration GuidingRespiratory-Gated Radiation Therapy
식별자
- Scopus EID
- 2-s2.0-85129558451
- KCI
- ART002829229



로그인
연구물 목록으로