Performance evaluation of STANDARD Q COVID-19 Ag home test for the diagnosis of COVID-19 during early symptom onset
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q2
- 저널
- JOURNAL OF CLINICAL LABORATORY ANALYSIS36(6) · #e24410 · 2022
- 피인용
- Web of Science 11Scopus 11
- FWCI (Scopus)
- 1.14
- JCR IF
- JCR 2021 3.124
- ISSN
- 0887-8013
저자
- Shin, Hyoshim제1저자Gyeongsang Natl Univ Hosp, Dept Lab Med, Jinju, South Korea
- Lee, SeungjunGyeongsang Natl Univ, Dept Lab Med, Changwon Hosp, Chang Won, South Korea
- Widyasari, KristinGyeongsang Natl Univ, Dept Lab Med, Changwon Hosp, Chang Won, South Korea
- 이종윤Pusan Natl Univ, Dept Lab Med, Sch Med, Busan, South Korea
- Bae, EunsinSeegene Inc, Seegene Inst Clin Res, Seoul, South Korea
- Kim, Sunjoo교신저자Gyeongsang Natl Univ, Dept Lab Med, Changwon Hosp, Chang Won, South Korea
초록
Background Surveillance and control of SARS-CoV-2 outbreak through gold standard detection, that is, real-time polymerase chain reaction (RT-PCR), become a great obstacle, especially in overwhelming outbreaks. In this study, we aimed to analyze the performance of rapid antigen home test (RAHT) as an alternative detection method compared with RT-PCR. Methods In total, 79 COVID-19-positive and 217 COVID-19-negative patients confirmed by RT-PCR were enrolled in this study. A duration from symptom onset to COVID-19 confirmation of <5 days was considered a recruiting criterion for COVID-19-positive cases. A nasal cavity specimen was collected for the RAHT, and a nasopharyngeal swab specimen was collected for RT-PCR. Results Sensitivity of the STANDARD Q COVID-19 Ag Home Test (SD Biosensor, Korea), compared with RT-PCR, was 94.94% (75/79) (95% [confidence interval] CI, 87.54%-98.60%), and specificity was 100%. Sensitivity was significantly higher in symptomatic patients (98.00%) than in asymptomatic (89.66%) patients (p-value = 0.03). There was no difference in sensitivity according to the duration of symptom onset to confirmation (100% for 0-2 days and 96.97% for 3-5 days, respectively) (p-value = 1.00). The RAHT detected all 51 COVID-19 patients whose Ct values were <= 25 (100%), whereas sensitivity was 73.33% (11/15) among patients with Ct values >25 (p-value = 0.01). Conclusion The RAHT showed an excellent sensitivity for COVID-19-confirmed cases, especially for those with symptoms. There was a decrease in sensitivity when the Ct value is over 25, indicating that RAHT screening may be useful during the early phase of symptom onset, when the viral numbers are higher and it is more transmissible.
키워드
식별자
- Scopus EID
- 2-s2.0-85128345199
- WoS UID
- 000783786300001



로그인
연구물 목록으로