Optimization of a lumbar interspinous fixation device for the lumbar spine with degenerative disc disease
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- PLOS ONE17(4 April) · 2022
- 피인용
- Web of Science 9Scopus 7
- FWCI (Scopus)
- 0.34
- JCR IF
- JCR 2021 3.752
- ISSN
- 1932-6203
저자
- 허민혁제1저자Pusan Natl Univ, Sch Mech Engn, Busan, South Korea
- 윤지환Pusan Natl Univ, Sch Mech Engn, Busan, South Korea
- 김한종Pusan Natl Univ, Sch Mech Engn, Busan, South Korea
- Lee, Sang-SooHallym Univ, Chuncheon Sacred Heart Hosp, Inst Skeletal Aging & Orthoped Surg, Chunchon, South Korea
- 박성훈교신저자Pusan Natl Univ, Sch Mech Engn, Busan, South Korea
초록
Copyright: © 2022 Heo et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Interspinous spacer devices used in interspinous fixation surgery remove soft tissues in the lumbar spine, such as ligaments and muscles and may cause degenerative diseases in adjacent segments its stiffness is higher than that of the lumbar spine. Therefore, this study aimed to structurally and kinematically optimize a lumbar interspinous fixation device (LIFD) using a full lumbar finite element model that allows for minimally invasive surgery, after which the normal behavior of the lumbar spine is not affected. The proposed healthy and degenerative lumbar spine models reflect the physiological characteristics of the lumbar spine in the human body. The optimum number of spring turns and spring wire diameter in the LIFD were selected as 3 mm and 2 turns, respectively—from a dynamic range of motion (ROM) perspective rather than a structural maximum stress perspective—by applying a 7.5 Nm extension moment and 500 N follower load to the LIFD-inserted lumbar spine model. As the spring wire diameter in the LIFD increased, the maximum stress generated in the LIFD increased, and the ROM decreased. Further, as the number of spring turns decreased, both the maximum stress and ROM of the LIFD increased. When the optimized LIFD was inserted into a degenerative lumbar spine model with a degenerative disc, the facet joint force of the L3-L4 lumbar segment was reduced by 56%–98% in extension, lateral bending, and axial rotation. These results suggest that the optimized device can strengthen the stability of the lumbar spine that has undergone interspinous fixation surgery and reduce the risk of degenerative diseases at the adjacent lumbar segments.
키워드
FINITE-ELEMENTINTRADISCAL PRESSUREGRAF LIGAMENTOPLASTYINTERVERTEBRAL DISCAXIAL ROTATIONFOLLOW-UPFUSIONLOADSBIOMECHANICSBONE
식별자
- Scopus EID
- 2-s2.0-85127887922
- WoS UID
- 000795077200030



로그인
연구물 목록으로