Experimental investigation of droplet parameters in a 2×2 rod bundle under air-water annular-mist flow
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER192 · 2022
- 피인용
- Web of Science 2Scopus 2
- FWCI (Scopus)
- 0.16
- JCR IF
- JCR 2021 5.431
- ISSN
- 0017-9310
저자
- 칼리드 카사오네제1저자Pusan Natl Univ, Dept Mech Engn, 63 Beon Gil 2, Busan 46241, South Korea
- 김태호Pusan Natl Univ, Dept Mech Engn, 63 Beon Gil 2, Busan 46241, South Korea
- 고영창Pusan Natl Univ, Dept Mech Engn, 63 Beon Gil 2, Busan 46241, South Korea
- 정재준Pusan Natl Univ, Dept Mech Engn, 63 Beon Gil 2, Busan 46241, South Korea
- 윤병조교신저자Pusan Natl Univ, Dept Mech Engn, 63 Beon Gil 2, Busan 46241, South Korea
초록
© 2022 Elsevier LtdAn experimental study was conducted to investigate the local droplet parameters for annular-mist air-water flow in a 2 × 2 rod bundle. It covered a flow condition of a superficial gas velocity (jg) range of 25–35 m/s (gas Reynold number (Reg) range of 39,132–54,785) and a superficial liquid velocity (jl) range of 0.015–0.040 m/s (liquid Reynold number (Rel) range of 432–1153) in an atmospheric pressure. From the test, the distributions of the local droplet parameters such as the droplet fraction, velocity, and diameter were measured by using a double sensor optical fiber probe (OFP). The effect of the superficial gas and liquid velocities on the local droplet parameters have been identified. Furthermore, the droplet mass flux over the measurement cross-section was obtained from the local droplet parameters distributions. It was found that the droplet mass flux has a decreasing trend with the superficial gas velocity and an increasing trend with superficial liquid velocity. That was attributed to the significant effect of the liquid film on the measured droplet mass flux and its trends. Moreover, the present droplet mass flux data were compared with the prediction of three existing droplet entrainment and deposition models. Finally, new entrainment and deposition rate models for predicting the droplet mass flux of a rod bundle were proposed and validated. The applicability of the proposed models is within the present experimental flow conditions range with a mean absolute percentage error (MAPE) of 10.34%.
키워드
Annular-mist flowDroplet depositionDroplet entrainmentLocal droplet parametersOptical fiber probe (OFP)Rod bundleMASS-TRANSFER RATEENTRAINMENT RATE2-PHASE FLOWSIZEFILMNONEQUILIBRIUMINTERCHANGEREGIME
식별자
- Scopus EID
- 2-s2.0-85127736389
- WoS UID
- 000799948600004



로그인
연구물 목록으로