Sustainable Antibacterial and Antiviral High-Performance Copper-Coated Filter Produced via Ion Beam Treatment
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- POLYMERS14(5) · 2022
- 피인용
- Web of Science 12Scopus 13
- FWCI (Scopus)
- 0.65
- JCR IF
- JCR 2021 4.967
- ISSN
- 2073-4360
저자
- Jung, Sunghoon제1저자Korea Inst Mat Sci, Dept Nanobio Convergence, Chang Won 51508, South Korea
- 양준영Pusan Natl Univ, Dept Organ Mat Sci & Engn, Busan 46241, South Korea
- Jang, DonghwanMasan Natl TB Hosp, Clin Res Ctr, Chang Won, South Korea
- Kim, TaeyoonMasan Natl TB Hosp, Clin Res Ctr, Chang Won, South Korea
- Baek, Ki HoKorea Inst Mat Sci, Dept Nanobio Convergence, Chang Won 51508, South Korea
- Yoon, HyunkyungKorea Inst Mat Sci, Dept Nanobio Convergence, Chang Won 51508, South Korea
- Park, Joo YoungKorea Inst Mat Sci, Dept Nanobio Convergence, Chang Won 51508, South Korea
- Kim, Sang KwonAiro Co Ltd, Goyang 10251, South Korea
- Hong, JinhyukAtomy Co Ltd, Gongju 32543, South Korea
- Ryoo, SungweonMasan Natl TB Hosp, Clin Res Ctr, Chang Won, South Korea
- Jang, Ho WonSeoul Natl Univ, Res Inst Adv Mat, Dept Mat Sci & Engn, Seoul 08826, South Korea
- Lee, Seunghun교신저자Korea Inst Mat Sci, Dept Nanobio Convergence, Chang Won 51508, South Korea
초록
© 2022 by the authors. Licensee MDPI, Basel, Switzerland.With the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), disease prevention has become incredibly important. Consequently, mask and air-purifier use has increased. The filter is the core component of these items. However, most filter materials lack antimicrobial properties. Copper is a sustainable antimicrobial material. When copper is deposited onto the filter’s surface, the microorganisms that come into contact with it can be effectively inactivated. In this study, we used an oxygen ion beam with a controlled process temperature to treat filter surfaces with copper. This enabled a strong adhesion of at least 4 N/cm between the copper and the filter fibers without damaging them. Upon exposing the filter to bacteria (Staphylococcus aureus ATCC 6538, Klebsiella pneumoniae ATCC 4352, Escherichia coli ATCC 25922, and Pseudomonas aeruginosa ATCC 27853) for one hour, a >99.99% removal rate was attained; when the filter was exposed to SARS-CoV-2 virus for one hour, it inactivated more than 99%. These beneficial properties minimize the risk of secondary infections, which are significantly more likely to occur when a conventional filter is replaced or removed.
키워드
식별자
- Scopus EID
- 2-s2.0-85126306918
- WoS UID
- 000768734100001



로그인