선박용 전자 유량계의 측정 정확도 향상을 위한 여자 코일 시스템의 영향에 관한 연구
A study on the effect of excitation coil system to improve measurement accuracy of electromagnetic flowmeter on the ship
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCIScopus
- 저널 순위
- Scopus Q4KCI Q2
- 저널
- 전기학회논문지70(10) · pp.1460 · 2021
- 피인용
- Scopus 3KCI 0
- FWCI (Scopus)
- 0.21
- ISSN
- 1975-8359
저자
초록
Copyright © The Korean Institute of Electrical Engineers.An electromagnetic flowmeter calculates the velocity of the fluid and volumetric flow rate by measuring the induced voltage generated by the internal magnetic field. However, because the velocity of the fluid changes according to various external conditions, the uniformity of the magnetic flux density in the measurement section is critical for the accurate measurement of the flow rate. In this study, an improved coil system was proposed to analyze the influence of the internal structure of the electromagnetic flowmeter and to increase the measurement accuracy. The proposed design was verified by analyzing the magnetic flux density distribution via 3D electromagnetic finite element analysis and via experiments using a manufactured prototype.
키워드
3D Finite element analysisElectromagnetic flowmeterFaraday’s LawFluid velocityMagnetic flux density
식별자
- Scopus EID
- 2-s2.0-85116960855
- KCI
- ART002762635



로그인
연구물 목록으로