본문 바로가기

Soft computing analysis of thermohydraulic enhancement using twisted tapes in a flat-plate solar collector: Sensitivity analysis and multi-objective optimization

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 29Scopus 33
FWCI (Scopus)
1.41
JCR IF
JCR 2020 9.297
ISSN
0959-6526

저자

  1. Mohseni-Gharyehsafa, Behnam제1저자Center for Energy Science and Technology, Skolkovo Institute of Science and Technology, 3 Nobel Street, Skolkovo, Moscow 121205, Russia
  2. 자바드School of Mechanical Engineering, Pusan National University, Busan 46241, Republic of Korea
  3. 김경천교신저자School of Mechanical Engineering, Pusan National University, Busan 46241, Republic of Korea
  4. Ouerdane, HenniCenter for Energy Science and Technology, Skolkovo Institute of Science and Technology, 3 Nobel Street, Skolkovo, Moscow 121205, Russia

초록

© 2021 Elsevier LtdFlat-plate solar collectors are a cost-effective technology for water heating in residential buildings. Comprehensive sensitivity analysis and multi-objective optimization of five crucial factors in a flat-plate solar collector equipped with twisted tapes are investigated. The studied factors are the Nusselt number (Nu), friction factor (f), solar collector efficiency (η), thermal performance factor (ξ), and the temperature difference of the heat transfer fluid across the device (ΔT). The simulation of functions is carried out by four soft computing methods, such as the linear and cubic form of multivariate adaptive regression splines (MARS), group method of data handling (GMDH), and multivariate polynomial regression (MPR). The linear form of the MARS algorithm shows the highest accuracy in predicting Nu, f, and η by R2 = 0.99986, 0.9984, and 0.98821, respectively. The Reynolds number (Re) is from 4000 to 14,000, and the twisted tape ratio (Y) is between 0 and 15. The simulated annealing optimization is employed to find the global optima. According to the study, Nu, η, ξ, and ΔT reach their maximum when f is minimum, which occurs for Y = 5 and Re in the 13,200 to 13,400 range for different global solar radiation levels. The maximum temperature difference happens at noon, about 6.54 K at the Re = 5362.5 and Y = 5 with the collector surface area by 2 m2. When the appropriate working conditions are met so that these factors are simultaneously optimal, ΔT, hence the efficiency, can be increased.

키워드

Flat-plate solar collectorMulti-objective optimizationRenewable energyTwisted tapes

식별자

Scopus EID
2-s2.0-85108331986
WoS UID
000709188300011