본문 바로가기

Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels

문서 유형
연구출판물 · 학술지 논문
등재
ESCIKCIScopus
저널 순위
KCI Q4
저널
NEUROINTERVENTION16(3) · pp.240 · 2021
피인용
Scopus 22KCI 1
FWCI (Scopus)
0.21
ISSN
2093-9043

저자

  1. Ihn, Yon-Kwon제1저자교신저자Department of Radiology, St. Vincent’s Hospital, The Catholic University of Korea, Suwon, Korea
  2. 김범수Department of Radiology, Seoul St. Mary’s Hospital, The Catholic University of Korea, Seoul, Korea
  3. 정해웅Department of Radiology, Busan Paik Hospital, Inje University, Busan, Korea
  4. 서상현Department of Radiology, Gangnam Severance Hospital, Yonsei University, Seoul, Korea
  5. 원유동Department of Radiology, Uijeongbu St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea
  6. 이영준Department of Radiology, Hanyang University College of Medicine, Seoul, Korea
  7. 김동준Department of Radiology, Severance Hospital, Yonsei Unviersity College of Medicine, Seoul, Korea
  8. 전평Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
  9. 류창우Department of Radiology, Kyung Hee University Hospital at Gangdong, Seoul, Korea
  10. 서상일Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea
  11. 최대섭Department of Radiology, Gyeongsang National University Hospital, Gyeongsang National University School of Medicine, Jinju, Korea
  12. 최시성Department of Radiology, Wonkwang University Hospital, Iksan, Korea
  13. 김상흠Department of Radiology, CHA Bundang Medical Center, CHA University, Seongnam, Korea
  14. 변준수Department of Radiology, Chung-Ang University Hospital, Seoul, Korea
  15. 노지은Department of Radiology, Pusan National University Yangsan Hospital, Yangsan, Korea
  16. 송윤선Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
  17. 정우상Department of Radiology, Ajou University Medical Center, Ajou University School of Medicine, Suwon, Korea
  18. 홍노아Department of Neurosurgery, Seoul National University Hospital, Seoul, Korea
  19. 백상현Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Korea
  20. 박정진Department of Neurology, Konkuk University Medical Center, Seoul, Korea
  21. 임수미Department of Radiology, Ewha Womans University Seoul Hospital, Seoul, Korea
  22. 김정재Department of Neurosurgery, Ewha Womans University Seoul Hospital, Seoul, Korea
  23. 윤웅Department of Radiology, Chonnam National University Hospital, Gwangju, Korea

초록

Purpose: To assess patient radiation doses during diagnostic and therapeutic neurointerventional procedures from multiple centers and propose dose reference level (RL). Materials and Methods: Consecutive neurointerventional procedures, performed in 22 hospitals from December 2020 to June 2021, were retrospectively studied. We collected data from a sample of 429 diagnostic and 731 therapeutic procedures. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time (FT), and total number of image frames (NI) were obtained. RL were calculated as the 3rd quartiles of the distribution. Results: Analysis of 1160 procedures from 22 hospitals confirmed the large variability in patient dose for similar procedures. RLs in terms of DAP, CAK, FT, and NI were 101.6 Gy·cm2, 711.3 mGy, 13.3 minutes, and 637 frames for cerebral angiography, 199.9 Gy·cm2, 3,458.7 mGy, 57.3 minutes, and 1,000 frames for aneurysm coiling, 225.1 Gy·cm2, 1,590 mGy, 44.7 minutes, and 800 frames for stroke thrombolysis, 412.3 Gy·cm2, 4,447.8 mGy, 99.3 minutes, and 1,621.3 frames for arteriovenous malformation (AVM) embolization, respectively. For all procedures, the results were comparable to most of those already published. Statistical analysis showed male and presence of procedural complications were significant factors in aneurysmal coiling. Male, number of passages, and procedural combined technique were significant factors in stroke thrombolysis. In AVM embolization, a significantly higher radiation dose was found in the definitive endovascular cure group. Conclusion: Various RLs introduced in this study promote the optimization of patient doses in diagnostic and therapeutic interventional neuroradiology procedures. Proposed 3rd quartile DAP (Gy·cm2) values were 101.6 for diagnostic cerebral angiography, 199.9 for aneurysm coiling, 225.1 for stroke thrombolysis, and 412.3 for AVM embolization. Continual evolution of practices and technologies requires regular updates of RLs.

키워드

Cerebral angiographyDiagnostic reference levelsRadiation monitoringIntracranial aneurysmThrombectomyIntracranial arteriovenous malformation

식별자

Scopus EID
2-s2.0-85166431834
KCI
ART002773596