본문 바로가기

Study of concrete de-bonding assessment technique for containment liner plates in nuclear power plants using ultrasonic guided wave approach

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q1Scopus Q2KCI Q2
저널
NUCLEAR ENGINEERING AND TECHNOLOGY54(5) · pp.1221 · 2022
피인용
Web of Science 8Scopus 9KCI 1
FWCI (Scopus)
0.65
JCR IF
JCR 2021 2.817
ISSN
1738-5733

저자

  1. 이용희제1저자Pusan Natl Univ, Grad Sch Mech Syst Design, Busan 46241, South Korea
  2. Yun, HyunminKorea Hydro & Nucl Power Co LTD, Gyeongju Si 38120, Gyeongsangbuk D, South Korea
  3. 조윤호교신저자Pusan Natl Univ, Grad Sch Mech Syst Design, Busan 46241, South Korea

초록

© 2021In this work, the guided wave de-bonding area-detecting technique was studied for application to containment liner plates in nuclear power plant areas. To apply this technique, an appropriate Lamb wave mode, symmetric and longitudinal dominance, was verified by the frequency shifting technique. The S0 2.7 MHz mm Lamb wave mode was chosen to realize quantitative experimental results and their visualization. Results of the bulk wave, longitudinal wave mode, and comparison experiments indicate that the wave mode was able to distinguish between the de-bonded and bonded areas. Similar to the bulk wave cases, the bonded region could be distinguished from the de-bonded region using the Lamb wave approach. The Lamb wave technique results showed significant correlation to the de-bonding area. As the de-bonding area increased, the Lamb wave energy attenuation effect decreased, which was a prominent factor in the realization of quantitative tomographic visualization. The feasibility of tomographic visualization was studied via the application of Lamb waves. The reconstruction algorithm for the probabilistic inspection of damage (RAPID) technique was applied to the containment liner plate to verify and visualize the de-bonding condition. The results obtained using the tomography image indicated that the Lamb wave-based RAPID algorithm was capable of delineating debonding areas.

키워드

Concrete debondingContainment liner plateGuided waveStructural health monitoringTomographyLAMB WAVESTOMOGRAPHYINSPECTIONARRAY