본문 바로가기

Experimental study of the effect of geometrical length to diameter ratios and heater orientations on sintered-based heat pipes thermal behavior

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
피인용
Web of Science 4Scopus 5
FWCI (Scopus)
0.32
JCR IF
JCR 2020 5.683
ISSN
0735-1933

저자

  1. 콜리 포스터 콰메제1저자Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63Beon Gil, Busan 46241, South Korea
  2. 칼라쓰 하리하란Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63Beon Gil, Busan 46241, South Korea
  3. 무찌 알베르토Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63Beon Gil, Busan 46241, South Korea
  4. 하만영Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63Beon Gil, Busan 46241, South Korea
  5. Chetwynd-Chatwin, JasonRolls Royce PLC, Whittle House,POB 3, Bristol BS34 7QE, Avon, England
  6. 민준기교신저자Pusan Natl Univ, Sch Mech Engn, 2 Busandaehak Ro 63Beon Gil, Busan 46241, South Korea

초록

© 2021 Elsevier LtdRecently, many studies have examined conventional heat pipes (CHP) for thermal solutions with higher dissipation rates and improved thermal management. However, several previous studies considered CHP with constant geometrical ratios. Therefore, this study experimentally investigated the time-based transient behaviors of sintered-based CHP with various length to diameter ratios (Lt/do) in the range of 30 to 100. By decreasing the Lt/do ratio from 100 to 30, the CHP thermal resistance was reduced from 0.75 °C/W to 0.05 °C/W. Generally, lower Lt/do ratios obtained by reducing the lengths or increasing the diameters of the CHP promote faster startup time and lower startup temperatures over broader operating conditions. In contrast, the higher Lt/do ratios arising from CHP with longer lengths or narrower diameters incite performance deterioration. Compared to other parameters investigated, the magnitude of heat input significantly governs the transient behavior of CHP. But, the maximum thermal limits depend mainly on the orientation mode. Tilting the CHP at acute and vertical orientations and lowering the Lt/do ratio promote recovery of performance decline. The CHP thermal performance showed exponential temperature responses under the operating parameters investigated. The present results can complement previous efforts, which studied heat pipes performance at fixed geometrical ratios.

키워드

Evaporation and condensation phenomenaHeat pipesLength to diameter ratioOrientation modesSintered wicksTransient thermal performancePERFORMANCEWICK

식별자

Scopus EID
2-s2.0-85119326410
WoS UID
000729672700001