본문 바로가기

Association between Thyroid Function and Heart Rate Moni tored by Wearable Devices in Patients with Hypothyroidism

문서 유형
연구출판물 · 학술지 논문
등재
KCISCIEScopus
저널 순위
JCR Q2Scopus Q2KCI Q2
저널
Endocrinology and Metabolism36(5) · pp.1121 · 2021
피인용
Web of Science 11Scopus 10KCI 0
FWCI (Scopus)
0.36
JCR IF
JCR 2020 4.01
ISSN
2093-596X

저자

  1. 김기훈제1저자Pusan Natl Univ, Dept Ind Engn, Busan, South Korea
  2. Lee, JuhuiThyroscope Inc, Ulsan, South Korea
  3. Ahn, Chang HoSeoul Natl Univ, Coll Med, Bundang Hosp, Dept Internal Med, 82 Gumi Ro 173 Beon Gil, Seongnam 13620, South Korea
  4. Yu, Hyeong WonSeoul Natl Univ, Coll Med, Bundang Hosp, Dept Surg, Seongnam, South Korea
  5. Choi, June YoungSeoul Natl Univ, Coll Med, Bundang Hosp, Dept Surg, Seongnam, South Korea
  6. Lee, Ho-YoungSeoul Natl Univ, Coll Med, Bundang Hosp, Dept Nucl Med, Seongnam, South Korea
  7. Lee, Won WooSeoul Natl Univ, Coll Med, Bundang Hosp, Dept Nucl Med, Seongnam, South Korea
  8. Moon, Jae Hoon교신저자Thyroscope Inc, Ulsan, South Korea

초록

Background: Heart rate (HR) monitored by a wearable device (WD) has demonstrated its clinical feasibility for thyrotoxicosis subjects. However, the association of HR monitored by wearables with hypothyroidism has not been examined. We assessed the association between serum thyroid hormone concentration and three WD-HR parameters in hypothyroid subjects. Methods: Forty-four subjects scheduled for radioactive iodine therapy (RAI Tx) after thyroid cancer surgery were included. Thirty subjects were prepared for RAI Tx by thyroid hormone withdrawal (hypothyroidism group) and 14 subjects by recombinant human thyrotropin (control group). Three WD-HR parameters were calculated from the HR data collected during rest, during sleep, and from 2:00 AM to 6:00 AM, respectively. We analyzed the changes in conventionally measured resting HR (On-site rHR) and WDHR parameters relative to thyroid hormone levels. Results: Serum free thyroxine (T4) levels, On-site rHR, and WD-HR parameters were lower in the hypothyroid group than in the control group at the time of RAI Tx. WD-HR parameters also reflected minute changes in free T4 levels. A decrease in On-site rHR and WD-HR parameters by one standard deviation (On-site rHR, approximately 12 bpm; WD-HR parameters, approximately 8 bpm) was associated with a 0.2 ng/dL decrease in free T4 levels (P<0.01) and a 2-fold increase of the odds ratio of hypothyroidism (P<0.01). WD-HR parameters displayed a better goodness-of-fit measure (lower quasi-information criterion value) than On-site rHR in predicting the hypothyroidism. Conclusion: This study identified WD-HR parameters as informative and easy-to-measure biomarkers to predict hypothyroidism.