본문 바로가기

Highly stable potentiometric sensor with reduced graphene oxide aerogel as a solid contact for detection of nitrate and calcium ions

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q1Scopus Q1
저널
JOURNAL OF ELECTROANALYTICAL CHEMISTRY897 · #115553 · 2021
피인용
Web of Science 53Scopus 61
FWCI (Scopus)
2.49
JCR IF
JCR 2020 4.464
ISSN
1572-6657

저자

  1. Kim, Min-Yeong제1저자Korea Inst Mat Sci, Surface Technol Div, 797 Changwon Daero, Chang Won 51508, Gyeongsangnam, South Korea
  2. 이종원Pusan Natl Univ, Sch Mat Sci & Engn, Busan 46241, South Korea
  3. Park, Da JungKorea Inst Mat Sci, Surface Technol Div, 797 Changwon Daero, Chang Won 51508, Gyeongsangnam, South Korea
  4. Lee, Joo-YulKorea Inst Mat Sci, Surface Technol Div, 797 Changwon Daero, Chang Won 51508, Gyeongsangnam, South Korea
  5. Myung, Nosang Vincent교신저자Univ Notre Dame, Dept Chem & Biomol Engn, Notre Dame, IN 46556 USA
  6. 권세훈교신저자Pusan Natl Univ, Sch Mat Sci & Engn, Busan 46241, South Korea
  7. Lee, Kyu Hwan교신저자Korea Inst Mat Sci, Surface Technol Div, 797 Changwon Daero, Chang Won 51508, Gyeongsangnam, South Korea

초록

Numerous reports have elucidated the importance of detecting of NO(3)(- )and Ca-2(+) ions for monitoring their levels to optimize crop growth. Herein, we prepared a reduced graphene oxide aerogel (rGOA) as a promising solid-contact material for manufacturing a highly stable solid contact ion-selective electrode (SC ISE) for monitoring to NO(3)(- )and Ca-2(+). The rGOA was synthesized through self-assembly of graphene oxide via heat treatment. Cyclic voltammetry and chronopotentilmetry were employed to demonstrate the fast charge transfer and large double layer capacitance of the rGOA layer modified electrode. The sensor comprising rGOA exhibited excellent Nernstian responses (59.1 mV/log [NO3- ] and 28.4 mV/log [Ca-2(+)]) and ion detection limbs (759 nM for NO(3)(- )and 186 nM for Ca-2(+)) due to its outstanding electrical conductivity and large surface area of rGOA. The Ag/AgCl electrode with a polyvinyl butyral (PVB) film was used as the reference electrode. Water layer tests and potentiometry confirmed that the long-term stability of the electrode improved owing to the hydrophobicity of rGOA. Furthermore NO(3)(- )and Ca-2(+) ions were detected in perilla leaf using the proposed ion-selective sensor, which was in agreement with the results of ion chromatography and inductively coupled plasma analyses. Thus, the proposed sensor provides an excellent sensing platform for the detection of inorganic ions in plant sap.

키워드

Potentiometric sensorIon sensorNO(3)(- )sensorCa2+ sensorReduced graphene oxide aerogelSELECTIVE ELECTRODESCARBONNITROGENGROWTHLAYER

식별자

Scopus EID
2-s2.0-85111693486
WoS UID