Design of drain tube with movable shutter in household refrigerators
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- INTERNATIONAL JOURNAL OF REFRIGERATION130 · 2021
- 피인용
- Web of Science 14Scopus 12
- FWCI (Scopus)
- 0.22
- JCR IF
- JCR 2020 3.629
- ISSN
- 0140-7007
저자
초록
The infiltration of warm and humid air from the outside into a freezer results in frost accumulation around the evaporator in household refrigerators. This can significantly reduce the cooling capacity of refrigerators. In this study, the pressure, temperature, and frost around a proposed drain tube were monitored through in-situ measurements until the first defrost process (about 54 h). The proposed drain tube has 220 times higher hydraulic resistance and shows 55 times lower inflow in computational fluid dynamics (CFD) analysis. Once the door of the freezer compartment is opened and closed, external warm air replaces the cold air in the freezer. Negative pressure is produced by the shrinkage of this external air under low-temperature conditions. The other role of the drain tube is to vent air between the outside and inside of the refrigerator under negative pressure. To release the negative pressure, the proposed drain tube has a movable shutter. In the CFD results, the secondary inlet increases the inflow by 3.2 times compared to the inflow in an I-type tube. To determine the design, the weight and inner diameter of the drain tube were changed. The performance of the proposed tube was validated by the lack of blockage of discharge until the first defrost process. The movable shutter did not allow the negative pressure to exceed -100 Pa by facilitating air venting after opening the door for 10 seconds and then closing it. (C) 2021 Elsevier Ltd and IIR. All rights reserved.
키워드
Household refrigeratorsDrain tubeAccumulation of frostIn-situ measurementsComputational fluid dynamics (CFD)HEAT-EXCHANGERPLAIN FINFROSTPERFORMANCEPREDICTIONADHESIONDEFROST
식별자
- Scopus EID
- 2-s2.0-85112498370
- WoS UID
- 000697350300004



로그인
연구물 목록으로