Visual Field Inference FromOptical Coherence Tomography Using Deep Learning Algorithms: A Comparison Between Devices
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q2
- 저널
- TRANSLATIONAL VISION SCIENCE & TECHNOLOGY10(7) · 2021
- 피인용
- Web of Science 23Scopus 25
- FWCI (Scopus)
- 1.64
- JCR IF
- JCR 2020 3.283
- ISSN
- 2164-2591
저자
- 신종훈제1저자Department of Ophthalmology, College of Medicine, Pusan National University Yangsan Hospital, Yangsan, South Korea
- 김성준Department of Ophthalmology, Pusan National University College of Medicine, Busan, Korea
- 김진미Department of Biostatistics, Clinical Trial Center, Biomedical Research Institute, Pusan National University Hospital, Busan, Korea
- 박건형교신저자Department of Ophthalmology, Busan Medical Center, Busan, Korea
초록
Purpose: To develop a deep learning model to estimate the visual field (VF) from spectral-domain optical coherence tomography (SD-OCT) and swept-source OCT (SS-OCT) and to compare the performance between them. Methods: Two deep learning models based on Inception-ResNet-v2 were trained to estimate 24-2 VF from SS-OCT and SD-OCT images. The estimation performance of the twomodels was evaluated by using the root mean square error between the actual and estimated VF. The performance was also compared among different glaucoma severities, Garway-Heath sectorizations, and central/peripheral regions. Results: The training dataset comprised images of 4391 eyes from 2350 subjects, and the test dataset was obtained from another 243 subjects (243 eyes). In all subjects, the global estimation errorswere 5.29 +/- 2.68 dB (SD-OCT) and 4.51 +/- 2.54 dB (SS-OCT), and the estimation error of SS-OCT was significantly lower than that of SD-OCT (P < 0.001). In the analysis of sectors, SS-OCT showed better performance in all sectors except for the inferonasal sector in normal vision and early glaucoma. In advanced glaucoma, the estimation error of the central region was worsened in both OCTs, but SS-OCT was still significantly better in the peripheral region. Conclusions: Our deep learning model estimated the VF 24-2 better with a wide field image of SS-OCT than did with retinal nerve fiber layer and ganglion cell-inner plexiform layer images of SD-OCT. Translational Relevance: This deep learning method can help clinicians to determine the VF fromOCT images. OCT manufacturers can equip this systemto provide additional VF data.
키워드
deep learningoptical coherence tomographyvisual fieldNERVE-FIBER LAYERTHICKNESS MEASUREMENTSGLAUCOMAREPRODUCIBILITYPROGRESSIONDISCRIMINATIONDIAGNOSISHUMPHREY
식별자
- Scopus EID
- 2-s2.0-85108171122
- WoS UID
- 000669229400001



로그인
연구물 목록으로