Improving Comfort and Air Conditioner Performance by Optimizing Controllers under Actual Usage Conditions

문서 유형
연구출판물 · 학술지 논문
등재
SCIEScopus
저널 순위
JCR Q2Scopus Q2
저널
APPLIED SCIENCES-BASEL11(11) · 2021
피인용
Web of Science 8Scopus 10
FWCI (Scopus)
0.28
JCR IF
JCR 2020 2.679
ISSN
2076-3417

저자

  1. Park, Taebyoung제1저자LG Electronics, 84, Wanarm-ro, Changwon-si, 51533, Korea
  2. Kim, ByungsoonLG Electronics, 84, Wanarm-ro, Changwon-si, 51533, Korea
  3. Hwang, GilunLG Electronics, 84, Wanarm-ro, Changwon-si, 51533, Korea
  4. 강율호Research Institute for Future Wind Energy Technology, Pusan National University, Busan, 46241, Korea
  5. 이인원Department of Naval Architecture and Ocean Engineering, Pusan National University, Busan, 46241, Korea
  6. 안영철교신저자Department of Architectural Engineering, Pusan National University, Busan, 46241, Korea

초록

This study is to increase the efficiency of the air conditioning system under actual conditions of use. In order to improve the increase in energy consumption due to control without considering indoor cooling load fluctuations, we review it compared to conventional control methods in two respects. First, we examined the control method to reduce energy consumption by varying the evaporative pressure of the system according to the cooling load, and secondly, further reducing energy consumption by controlling the revolutions per minute (RPM) of the fan of the indoor unit at the same time as the pressure fluctuation under the cooling load. We found that changing the target pressure depending on the difference between the target temperature and room temperature can control temperature more efficiently and save energy than using fixed target pressure, and that the effect increases when applying the control of the air volume of the indoor air. Cleaning up the resulting values, the fan-load-control condition of the cooling-load-estimation control method showed an energy savings effect of 16.1-48.7% compared with the fixed-pressure control method and 1.2-37.7% compared with the cooling-load-estimation control method.

키워드

control methodoptimizing controllerair conditionerenergy efficiencyHEAT-PUMPSTRATEGY