Chimerism Assay Using Single Nucleotide Polymorphisms Adjacent and in Linkage-Disequilibrium Enables Sensitive Disease Relapse Monitoring after Hematopoietic Stem-Cell Transplantation
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q1Scopus Q1
- 저널
- CLINICAL CHEMISTRY67(5) · pp.781 · 2021
- 피인용
- Web of Science 7Scopus 7
- FWCI (Scopus)
- 0.33
- JCR IF
- JCR 2020 8.327
- ISSN
- 0009-9147
저자
- Kim, JinJu제1저자Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, South Korea
- 윤우빈Brain Korea 21 PLUS Project for Medical Science, Yonsei University, Seoul, South Korea
- Park, Yu JinDepartment of Laboratory Medicine, Yonsei University College of Medicine, Seoul, South Korea
- Seo, JieunDepartment of Laboratory Medicine, Yonsei University College of Medicine, Seoul, South Korea
- Lee, Richard Dong WookDxome Co. Ltd, Seongnam-si, Gyeonggi-do, South Korea
- Shin, SaeamDepartment of Laboratory Medicine, Yonsei University College of Medicine, Seoul, South Korea
- 이현지Department of Laboratory Medicine, Pusan National University, Yangsan Hospital, Yangsan, South Korea
- 김인숙Department of Laboratory Medicine, Pusan National University, School of Medicine, Pusan, South Korea
- Choi, Jong RakDepartment of Laboratory Medicine, Yonsei University College of Medicine, Seoul, South Korea
- Lee, Seung-Tae교신저자Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, South Korea
초록
BACKGROUND: Short tandem repeat (STR)-based chimerism analysis has been widely used for chimerism monitoring after hematopoietic stem-cell transplantation (HSCT), but technical artifacts can be problematic. We designed a chimerism assay using single nucleotide polymorphisms (SNPs) adjacent and in linkage-disequilibrium (CASAL), which doubly checked for SNP pairs, and thus could reduce background errors and increase analytical sensitivity. METHODS: CASAL targeted 84 SNP pairs within 10 bp distance and in perfect linkage-disequilibrium. Using undiluted and serially diluted samples, baseline error rates, and linearity was calculated. Clinical performance of CASAL was evaluated in comparison with a conventional STR assay, using 191 posttransplant samples from 42 patients with HSCT. RESULTS: CASAL had similar to 10 times lower baseline error rates compared to that of ordinary next-generation sequencing. Limit of detection and quantification of CASAL were estimated to be 0.09 and 0.39%, respectively, with a linear range of 0.1-100%. CASAL correlated well with STR assay (r(2) = 0.99) and the higher sensitivity enabled detection of low-level recipient chimerism and earlier prediction of relapse. CONCLUSIONS: CASAL is a simple, analytically sensitive and accurate assay that can be used in clinical samples after HSCT with a higher performance compared to that of traditional assays. It should also be useful in other forensic and archeological testing.
키워드
BONE-MARROW-TRANSPLANTATIONMIXED CHIMERISMDONOR CHIMERISMDIGITAL PCRQUANTIFICATION
식별자
- Scopus EID
- 2-s2.0-85105894110
- WoS UID
- 000646195800014



로그인