Gold Standard? Method of Citric Acid Solution Swallowing Test as a Screening Test for Patients with Tracheostomy
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- SCIEScopus
- 저널 순위
- JCR Q2Scopus Q1
- 저널
- DYSPHAGIA37(3) · pp.533 · 2022
- 피인용
- Web of Science 2Scopus 2
- FWCI (Scopus)
- 0.15
- JCR IF
- JCR 2021 2.733
- ISSN
- 0179-051X
저자
- 김상훈제1저자Department of Rehabilitation Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro Seo-Gu, Busan, 602-739, Republic of Korea
- 김동민Department of Rehabilitation Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro Seo-Gu, Busan, 602-739, Republic of Korea
- 박호은Department of Rehabilitation Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro Seo-Gu, Busan, 602-739, Republic of Korea
- 신용범Department of Rehabilitation Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro Seo-Gu, Busan, 602-739, Republic of Korea
- 이병주Department of Rehabilitation Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro Seo-Gu, Busan, 602-739, Republic of Korea
- 장명훈Department of Rehabilitation Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro Seo-Gu, Busan, 602-739, Republic of Korea
- 윤진아교신저자Department of Rehabilitation Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, 179 Gudeok-Ro Seo-Gu, Busan, 602-739, Republic of Korea
초록
This study aimed to apply various ranges of citric acid levels in the mouth and T-cannula to compare the validity with instrumental aspiration measures in patients with tracheostomy. Sixty-one patients underwent the citric acid cough reflex test (CRT) and videofluoroscopic swallowing study (VFSS). Citric acid was delivered via facemask and T-cannula at concentrations of 0.4 mol/L, 0.6 mol/L, and 0.8 mol/L. Further, we recorded the coughing count and presence of >= 2 (C2) and >= 5 (C5) coughs. CRT via facemask at 0.4 mol/L C2, 0.6 mol/L C5, and 0.8 mol/L C2 and C5 were significantly associated with the presence of tracheal aspiration during VFSS. The sensitivity and specificity were optimized at 0.8 mol/L C2 for mouth inhalation and at 0.8 mol/L C5 for T-cannula inhalation. There was a significant difference in the coughing count during CRT at 0.4 mol/L and 0.8 mol/L via mouth inhalation between patients with or without tracheal aspiration, but not via T-cannula. The AUC for 0.8 mol/L facemask inhalation was 0.701. The optimal cut-off value of coughing count was thrice with 84.62% sensitivity and 50.00% specificity on the ROC curve. Afferent sensory nerve desensitization around and below the tracheostomy site could affect coughing reflex initiation and decrease the sensitivity of detecting aspiration in tracheotomized patients. The citric acid CRT via facemask can reliably detect tracheal aspiration and presence of coughing reflex compared to that via T-cannula in patients with tracheostomy.
키워드
SwallowingTracheostomyCitric acidCough reflex testSILENT ASPIRATIONCOUGH
식별자
- Scopus EID
- 2-s2.0-85105369180
- WoS UID
- 000644792300001



로그인
연구물 목록으로