A laser-based monitoring system for a deep-inspiration breath-hold in radiation treatment of breast cancer: feasibility study
- 문서 유형
- 연구출판물 · 학술지 논문
- 등재
- KCISCIEScopus
- 저널 순위
- JCR Q4Scopus Q4KCI Q4
- 저널
- JOURNAL OF THE KOREAN PHYSICAL SOCIETY79(1) · pp.105 · 2021
- 피인용
- Web of Science 3Scopus 3KCI 1
- FWCI (Scopus)
- 0.07
- JCR IF
- JCR 2020 0.649
- ISSN
- 0374-4884
저자
- 김동운제1저자Department of Radiation Oncology and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
- 전호상Department of Radiation Oncology and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
- 주지현Department of Radiation Oncology and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, South Korea
- 기용간교신저자Department of Radiation Oncology, Pusan National University School of Medicine, Yangsan, South Korea
- 김원택Department of Radiation Oncology, Pusan National University School of Medicine, Yangsan, South Korea
- 김동현Department of Radiation Oncology, Pusan National University School of Medicine, Yangsan, South Korea
- 박달Department of Radiation Oncology, Pusan National University Hospital, Busan, South Korea
- 남지호Department of Radiation Oncology, Pusan National University Hospital, Busan, South Korea
초록
A deep-inspiration breath-hold (DIBH) is a useful technique that can reduce the risk of radiation-related toxicity to major organs during radiation treatment (RT) of breast cancer. A laser sensor-based position monitoring system was developed to measure the absolute position of the object and to realize high accuracy and reproducibility during DIBH. A laser distance sensor (LDS) was manufactured to be mounted on a commercial breast board and to measure the absolute distance between the sensor and the patient's sternum. The absolute distance measured by using the LDS was evaluated for the movement generated by the motorized jack system. The respiration of five volunteers was measured by using the LDS and commercial real-time position management (RPM) to evaluate the correlation of the signals. The data measured by using the LDS for the input to the motorized jack had a relative error of 0.2%. At DIBH, the average correlation coefficient between the LDS and RPM was 0.98, and at FB, it was 0.84. The LDS and RPM showed almost similar timings for the rising and the falling portions, but the magnitudes of amplitudes were slightly different from each other. The LDS proposed in this study can easily reproduce patient setup and monitor DIBH without any disturbance from the treatment beam. The measuring accuracy of the LDS for the quantitative motion of a motorized jack system was successfully verified. The performance of the LDS compared to RPM in the FB and the DIBH of five volunteers was also clinically acceptable.
키워드
Deep inspiration breath holdLaser distance sensorBreast cancerRadiotherapy