Case series of ventriculoatrial shunt placement in hybrid room: Reassessment of ventriculoatrial shunt

문서 유형
연구출판물 · 학술지 논문
등재
KCIScopus
저널 순위
Scopus Q4
저널
Korean Journal of Neurotrauma16(2) · pp.181 · 2020
피인용
Scopus 5KCI 0
FWCI (Scopus)
0
ISSN
2234-8999

저자

  1. 김영하제1저자Department of Neurosurgery, Pusan National University Yangsan Hospital, Pusan, Korea
  2. 이상원교신저자Department of Neurosurgery, Pusan National University Yangsan Hospital, Pusan, Korea
  3. 김동현Department of Surgery, Pusan National University Yangsan Hospital, Pusan, Korea
  4. 이치형Department of Neurosurgery, Pusan National University Yangsan Hospital, Pusan, Korea
  5. 김창현Department of Neurosurgery, Pusan National University Yangsan Hospital, Pusan, Korea
  6. 성순기Department of Neurosurgery, Pusan National University Yangsan Hospital, Pusan, Korea
  7. 손동욱Department of Neurosurgery, Pusan National University Yangsan Hospital, Pusan, Korea
  8. 송근성Department of Neurosurgery, Pusan National University Yangsan Hospital, Pusan, Korea

초록

Object: Ventriculoatrial shunt (VAS) remains an alternate option for treatment ofhydrocephalus in patients with ventriculoperitoneal shunt (VPS) failure. Unfamiliar anatomyfor a neurosurgeon has resulted in the VAS falling out of favor as a treatment option. However, there are unsatisfactory reports on the long-term result of VPS, and VAS has beenrecently re-evaluated. We are to report the simple way to do the VAS using a peel-away sheathin a hybrid operation room. Methods: A jugular vein path was drawn by ultrasound, a small incision was made above theclavicle, and a shunt catheter was tunneled into it. The jugular vein was punctured beside thetunneled catheter with a Seldinger needle under ultrasound guidance. A flexible guide wirewas introduced into the vein and 6-Fr peel-away sheath was advanced into the vein along thewire. Under fluoroscopic guidance, the catheter was cut to position approximately midlevel in the atrium. Afer the guide wire was removed, the distal shunt catheter was passeddown. Afer confrming proper position of the distal catheter under the fluoroscope, thecatheter-guiding sheath was pulled out as a peeling-away manner. We performed this surgicalprocedures in 5 cases. Results: All the procedures of the VAS using a peel-away sheath were performed in a hybridoperation room Of 5 patients, 3 patients had the distal catheter failures in the peritoneal cavityand 2 patients had shunt A distal catheter was successfully indwelling in all the cases withoutany difculties. Afer the surgery, neither shunt infection nor thromboembolic event happened. Conclusion: VAS using fluoroscopy and a peel-away sheath is a good alternative option forhydrocephalus patients with shunt failure related to peritoneal cavity complications.

키워드

FluoroscopyHybridHydrocephalusOperating roomVentriculoatrial shuntsVentriculoperitoneal shunt